Signals connector - J3 (MBA-DBP/3UE and MBA-DBP/6UE)

 

 

 

 

 

 

 

Pin

Function

 

 

 

Remarks

 

 

 

 

 

 

 

 

1

positive

input

of

a

See Appendix C.

 

 

differential amplifier.

 

 

2

Negative

input

of

a

See Appendix C.

 

 

differential amplifier.

 

 

3

Output

of

 

a

See Appendix C.

 

 

differential amplifier.

 

 

4

Circuit common

 

 

 

 

5

Analog input

 

 

This input is monitored by the main μP. When Vi

 

 

 

 

 

< 5V, R1=470ohm should be inserted. When Vi>

 

 

 

 

 

5V, R1(Kohm)=2Vi-10 should be inserted. The

μP

 

 

 

 

 

always reads a range of +5V.

 

6

Circuit common

 

 

 

 

7

Circuit common

 

 

 

 

8

Current monitor

 

 

This analog output represents the actual current

 

 

 

 

 

in the motor. The scale (in A/V) is: Ip / 7.5

 

 

 

 

 

 

Ip - Rated peak current of amplifier.

 

9

Circuit common

 

 

 

 

10

+5V output

 

 

 

There are several +5V pins. The accumulative

 

 

 

 

 

 

external load should not exceed 200mA.

 

11

+15V output

 

 

There are several +15V pins. The accumulative

 

 

 

 

 

 

external load should not exceed 100mA.

 

12

-15V output

 

 

There are several -15V pins. The accumulative

 

 

 

 

 

 

external load should not exceed 100mA.

 

13

Channel B output

 

 

 

 

14

Channel A output

 

 

 

 

15

Index output

 

 

For resolver option only.

 

16

Not connected

 

 

 

 

17

Inhibit output

 

 

Relay contact (potential free).

 

 

 

 

 

 

The relay contact is closed whenever

the

 

 

 

 

 

amplifier is enabled. Contact rating: 0.5A, 200V,

 

 

 

 

 

10W.

 