83
6.5.9Pulse/Direction signals wiring
PULSE & DIRECTION INPUT CONNECTION
J6 |
|
| |
15 | 8 |
| |
14 | 7 |
| |
13 | 6 | CONTROLLER | |
12 | 5 | ||
| |||
11 | 4 |
| |
10 | 3 | PULSE | |
9 | 2 | DIRECTION | |
| 1 | ||
|
|
|
| DIFFERENTIAL PULSE & DIRECTION | |
J6 |
| INPUT CONNECTION | |
| 8 |
| |
14 | 7 |
| |
6 | CONTROLLER | ||
13 | 5 |
| |
12 | 4 | - PULSE | |
11 | 3 | ||
PULSE | |||
10 | 2 | DIRECTION | |
9 | 1 | - DIRECTION | |
|
|
NOTES:
1.THE METAL FRAME OF J6 AND PIN 8 ARE INTERNALLY CONNECTED TO THE DCB COMMON. THE SHIELDING SHOULD BE CONNECTED EITHER TO J6 PIN 8 OR TO THE METAL FRAME OF J6.
SYMBOLS:
TWISTED PAIR
SHIELDING