Emerson 3000 instruction manual World Class, Instruction Bulletin, Appendices J-11

Models: 3000

1 184
Download 184 pages 52.9 Kb
Page 177
Image 177
Appendices J-11

World Class 3000

Instruction Bulletin

Appendix J Rev. 1.2 May 2005

DOES

HART UNIT NO HAVE

POWER

?

YES

DOES

HART UNIT NO INDICATE BATTERY POWER

GOOD

?

YES

IS

HART UNIT NO BEING USED

"ON-LINE"

?

YES

REPLACE BATTERIES. IF APPLICABLE, RECHARGE NiCad BATTERIES.

VERIFY HART IS CONFIGURED FOR IFT. REFERENCE OFF-LINE CONFIGURATION (HART POCKET-SIZED MANUAL).

IS

NO

HART UNIT

 

RECONFIGURE HART UNIT

CONFIGURED

 

FOR IFT.

FOR IFT?

 

 

YES

IS IFT

NO

SUPPLY POWER TO IFT.

POWERED

?

YES

IS IFT

NO

 

EXPERIENCING

 

 

FAULTS

 

?

 

YES

CLEAR IFT OF ALL FAULT

CONDITIONS.

DOES

IFT HAVENO MICROPROCESSOR

BOARD

REV.#

3039513G

?

YES

(GO TO

SHEET 2 OF 2)

CONTACT SERVICE

REPRESENTATIVE.

686004

Figure J-5. Model 275D9E, Troubleshooting Flowchart (Sheet 1 of 2)

Rosemount Analytical Inc. A Division of Emerson Process Management