Installing and Removing the Module

Hardware Preparation and Installation

 

 

Table 2-3 Switch Settings

Switch

SW1-1

SW1-2

SW1-3

SW1-4

Description

Reserved (OFF: default value)

Reserved (OFF: default value)

Restores default static IP addresses

OFF: Dynamic IP addresses are assigned by the ATCA-M100, for details refer to Table "MIB Browser Settings" on page 37 (default)

ON: Static IP addresses are assigned

192.168.21.40: acces via ETHA on ARTM-F103-STX

192.168.22.40: acces via ETHB on ARTM-F103-STX

Reserved (OFF: default value)

2.4Installing and Removing the Module

The PMC-CGM can be installed on the PMC slot of the AdvancedTCA ATCA-F103 blade.

Figure 2-2 Location of PMC Slot on ATCA-F103

PMC-CGM Installation and Use (6806800D53C)

29

Page 29
Image 29
Emerson PMC-CGM manual Installing and Removing the Module, Switch Settings