MIB Description

5

5.1Overview

You can use the CGM-CONTROL-MIB to access and control the clock generator module PMC- CGM that is used in your AdvancedTCA system.

It is located at

.iso.org.dod.internet.private.enterprises.forceComputers.cgmControlMIB.motCgm (OID:

.1.3.6.1.4.1.3656.8152.1).

The CGM-CONTROL-MIB contains the following three main branches.

Table 5-1 MIB Structure

Branch

Used for...

 

 

cgmControl

Controlling and configuring the BITS interfaces and the PLL

 

 

cgmSys

Maintianing the PMC-CGM (FW/SW upgrade, event log)

 

 

cgmClkDist

Distributing clocks in the chassis

 

 

5.2cgmControl

The cgmControl branch contains the following information:

zcgmInputTable - for details refer to Table 5-2 on page 47.

For details on how to use these MIB objects refer to Configure the Reference Clock on page 41.

zcgmBitsTable - for details refer to Table 5-4 on page 49.

For details on how to use these MIB objects refer to Configure the BITS Interface on page 39.

zVarious MIB objects that are described in Table 5-5 on page 53.

For details on how to use these MIB objects refer to Configure the Interface Mode on page 39, Configure Initial Master/Slave Role on page 40.

The cgmInputTable (OID: .1.3.6.1.4.1.3656.8152.1.1.1) uses the instance number as defined in Table "Input Assignments" on page 48 as index.

Table 5-2 cgmInputTable

OID

MIB Object

Description

Access

 

 

 

 

.1.1.1.1.2

cgmInputName

Named source for this input. If the string is

r

 

 

empty the input is not connected.

 

 

 

 

 

PMC-CGM Installation and Use (6806800D53C)

47