Configure the Interface Mode

Access and Configuration

 

 

4.4.3Configure the Interface Mode

You can chose between SONET/T1 and SDH/E1 mode via the MIB object cgmInterfaceMode OID: .1.3.6.1.4.1.3656.8152.1.1.10.0. The modes are used in different regions.

Table 4-2 Interface Modes

Mode Type

MIB Value

Purpose

 

 

 

SONET/T1

0

USA

 

 

 

SDH/E1

1 (default)

Europe/Asia

 

 

 

This entry determines whether an input frequency of 1544KHz (Sonet/T1) or 2048KHz (SDH/E1) can be selected for the cgmInputFrequency object (OID:.1.3.6.1.4.1.3656.8152.1.1.1.1.3).

Configuring the interface mode

To configure the interface mode of the PMC-CGM, proceed as follows:

1.Start SNMP manager or MIB browser.

2.Connect to the PMC-CGM using one of its IP addresses.

3.Go to object cgmInterfaceMode OID: .1.3.6.1.4.1.3656.8152.1.1.10.0.

4.Check whether the default value meets your requirements. Otherwise, change the value as required.

4.4.4Configure the BITS Interface

The interface mode determines whether the BITS interface operates in E1 (default value) or T1 mode.

Configuring the BITS interface

To set the line type and line code of the BITS interface, proceed as follows:

1.Start SNMP manager or MIB browser.

2.Connect to the PMC-CGM using one of its IP addresses.

3.In cgmBitsTable OID: .1.3.6.1.4.1.3656.8152.1.1.2 go to object dsx1LineCode OID:

.1.3.6.1.4.1.3656.8152.1.1.2.1.5 and select desired line code value.

For details on the available values refer to Table "cgmBitsTable" on page 49.

4.In cgmBitsTable OID: .1.3.6.1.4.1.3656.8152.1.1.2 go to object dsx1LineType OID:

.1.3.6.1.4.1.3656.8152.1.1.2.1.4 and select desired line type value.

For details on the available values refer to Table "cgmBitsTable" on page 49.

PMC-CGM Installation and Use (6806800D53C)

39

Page 39
Image 39
Emerson PMC-CGM manual Configure the Interface Mode, Configure the Bits Interface, Configuring the interface mode