Safety Notes

Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes or modifications not expressly approved by Emerson could void the user's authority to operate the equipment. A proper installation in a compliant system will maintain the required performance. Use only shielded cables when connecting peripherals to assure that appropriate radio frequency emissions compliance is maintained.

Operation

Product Damage Surface

High humidity and condensation on the product surface causes short circuits.

Do not operate the product outside the specified environmental limits. Make sure the product is completely dry and there is no moisture on any surface before applying power.

Overheating and Product Damage

Operating the product without forced air cooling may lead to overheating and thus damage of the product.

When operating the product, make sure that forced air cooling is available in the shelf.

Installation

Damage of Circuits

Electrostatic discharge and incorrect installation and removal of the product can damage circuits or shorten their life.

Before touching the product or electronic components, make sure that your are working in an ESD-safe environment.

Product Damage

Incorrect installation of the product can cause damage of the product.

Only use handles when installing/removing the product to avoid damage/deformation to the face plate and/or PCB.

Damage to Product/Backplane or System Components

Bent pins or loose components can cause damage to the product, the backplane, or other system components.

Therefore, carefully inspect the product and the backplane for both pin and component integrity before installation.