Emerson PMC-CGM manual

Models: PMC-CGM

1 66
Download 66 pages 1.17 Kb
Page 56
Image 56

MIB DescriptioncgmSys

Table 5-6 cgmEventTable (continued)

OID

MIB Object

Description

Access

 

 

 

 

.1.3.1.1.4

cgmEventCode

A pre-defined event code - for details refer to Table 5-7 on

r

 

 

page 56.

 

 

 

 

 

.1.3.1.1.5

cgmEventData

Event specific data

r

 

 

 

 

.1.3.1.1.6

cgmEventDescr

Textual event description

r

 

 

 

 

The following table lists all event codes and their severity. Events which cause the module to give up mastership are marked with an asterisk in the "severity" column.

Table 5-7 Event Codes and Severity

Code

Severity

Description

 

 

 

inputChanged (1)

Event

The selected PLL input has changed.

 

 

 

lostLock (2)

Event

The T0 PLL lost lock and enters holdover mode.

 

 

 

gainedLock (3)

Event

The PLL gained lock.

 

 

 

nowMaster (4)

Event

The module has acquired mastership.

 

 

 

nowSlave (5)

Event

The module has entered slave mode.

 

 

 

validInputsChanged (6)

Event

The validity or more of the PLL inputs has changed .

 

 

 

selectedInputFailed (7)

Event

The selected clock input has failed.

 

 

 

dpllInitError (10)

Warning

Error while initializing the DPLL.

 

 

 

freqValidationError( 11)

Warning

One of the clock sources measured in the FPGA is out

 

 

of range.

 

 

 

inputStateChange (12)

Event

Reported when a state change is detected by the

 

 

activity monitor.

 

 

EventData: Upper 16 bits encode the new state, lower

 

 

16 bits encode the input number.

 

 

State can be

 

 

0 (working)

 

 

1 (failing)

 

 

2 (failed)

 

 

3 (recovering)

 

 

4 (unknown)

 

 

This is the same information as presented in the

 

 

cgmInputActivityMonitor element.

 

 

 

lineCardClkError (20)

Warning

Not applicable for PMC-CGM.

 

 

 

lineCardClkSelected (21)

Event

Not applicable for PMC-CGM.

 

 

 

bitsRlof/c (30/34)

Event

"Loss of frame" / "Loss of frame cleared" event

 

 

detected on a BITS interface.

 

 

EventData: The BITS interface on which the event has

 

 

been detected (0 or 1).

 

 

 

56

PMC-CGM Installation and Use (6806800D53C)

Page 56
Image 56
Emerson PMC-CGM manual