To access the PMC-CGM, you have to attach an Ethernet cable to the ARTM-F103-STX as shown in the following graphic.

It is mandatory that you connect port ETH7 with ETHA on the same ARTM-F103-STX and that you cross-connect ETH8 with ETHB on the peer ARTM-F103-STX as indicated below.

Figure 4-1 Connecting the ARTM-F103-STX Ethernet Ports

4.2.2Access

To access the module you can either use IPMI or a MIB browser.

For details on how to access the module via IPMI refer to the PMC-CGM: Control via IPMI Programmer’s Reference.

When using a MIB browser, you have to specify the settings described in Using a MIB Browser on page 37.