Emerson PMC-CGM manual

Models: PMC-CGM

1 66
Download 66 pages 1.17 Kb
Page 38
Image 38

Access and Configuration

Define IP Address of the Protection Partner Module

 

 

You can perform these tasks independently from each other.

4.4.1Define IP Address of the Protection Partner Module

The PMC-CGM modules usually work in a master/slave configuration. The protection partner is the other PMC-CGM module, regardless of the master/slave role. The default partner address is configured according to the IP address configuration described in Table "MIB Browser Settings" on page 37.

Defining the IP address of the protection partner module

To define the IP address via the MIB, process as follows:

1.Start SNMP manager or MIB browser.

2.Connect to the PMC-CGM using one of its IP addresses.

3.In object cgmProtectionPartnerAddress OID: .1.3.6.1.4.1.3656.8152.1.1.22.0 set the IP address of the partner PMC-CGM module.

4.4.2Define SNMP Trap Destinations

The PMC-CGM firmware keeps an event log which captures errors, warnings and informative messages in a RAM buffer. The event log can always be accessed via SNMP. Additionally, it is possible to configure the firmware so that each entry up to a certain severity level is posted as an SNMP trap to a specified destination.

Defining SNMP Trap Destinations

To define SNMP trap destinations, proceed as follows:

1.Start SNMP manager or MIB browser.

2.Connect to the PMC-CGM using one of its IP addresses.

3.Go to object cgmBootString OID:.1.3.6.1.4.1.3656.8152.1.3.33.

4.Enter IP address to which the SNMP traps have to be sent in the hhosttrapDest parameter.

This setting is stored persitently in the NVRAM of the module and is applied after the next reboot.

5.Go to object cgmTrapDestination OID: .1.3.6.1.4.1.3656.8152.1.3.32.0.

6.Enter IP address to which the SNMP traps have to be sent.

This setting is only valid until the next reboot. After the reboot, the default IP address defined via the cgmBootString object is applied.

38

PMC-CGM Installation and Use (6806800D53C)

Page 38
Image 38
Emerson PMC-CGM manual