Emerson PMC-CGM DC Module Power Requirements, RequirementsHardware Preparation and Installation

Models: PMC-CGM

1 66
Download 66 pages 1.17 Kb
Page 27
Image 27

RequirementsHardware Preparation and Installation

Table 2-1 Environmental Requirements

Feature

Operating

Non-Operating (packed state)

 

 

 

Temperature

+5ºC (+41°F) to +40ºC (+104°F)

-40ºC (-40°F) to +85ºC (+185°F)

 

(normal operation) according to NEBS

 

 

Standard GR-63-CORE

 

 

-5°C (+23°F) to +55°C (+131°F)

 

 

(exceptional operation) according to

 

 

NEBS Standard GR-63-CORE

 

 

 

 

Temp. change

+/- 0.25ºC/min according to NEBS

+/- 0.25ºC/min

 

Standard GR-63-CORE

 

 

 

 

Relative humidity

5% to 90% non-condensing according

5% to 95% non-condensing according to

 

to Emerson-internal environmental

Emerson-internal environmental

 

requirements

requirements

 

 

 

Vibration (tested

0.1 g from 5 to 100 Hz and back to 5 Hz

5-20 Hz at 0.01 g2/Hz

in target platform)

at a rate of 0.1 octave/minute.

20-200 Hz at -3.0 dB/octave

 

 

 

 

Random 5-20 Hz at 1 m2/Sec3

 

 

Random 20-200 Hz at -3 dB/octave

 

 

 

Shock

Half-sine, 11 mSec, 30 m/Sec2

Blade level packaging

 

 

Half-sine, 6 mSec at 180 m/Sec2

Free fall

-

200 mm/all edges and corners

 

 

1.0 m (packaged) per ETSI 300 019-2-2

 

 

(Blade level packaging)

 

 

100 mm (unpackaged) per GR-63-

 

 

CORE

 

 

 

2.2.2.2Power Requirements

Make sure that the module is only used on an ATCA-F103 blade in an AdvancedTCA shelf connected to -48VDC up to -60VDC (rated voltage), according to Telecommunication Network Voltage (TNV-2).

A TNV-2 circuit is a circuit whose normal operating voltages exceed the limits for a safety-extra- low-voltage (SELV) under normal operating conditions, and which is not subject to overvoltages from telecommunication networks.

Table 2-2 DC Module Power Requirements

Feature

Value

 

 

Rated Voltage

3.3V

 

 

Operating Voltage

3.3V +/-3%

 

 

Input current

1.5A

 

 

PMC-CGM power dissipation

5W (max.)

 

 

PMC-CGM Installation and Use (6806800D53C)

27

Page 27
Image 27
Emerson PMC-CGM manual DC Module Power Requirements, RequirementsHardware Preparation and Installation, Feature Value