Vertical shift (image)

Command/response table for SIS commands (continued)

Command

ASCII (Telnet)

Response

Additional description

(host to switcher)

(switcher to host)

 

 

 

 

 

 

Vertical shift (image)

 

 

 

Specific value

2 * X50@ * X52! /

Increment vertical image shift

2

* X50@ + /

Decrement vertical image shift

2

* X50@ – /

View vertical image shift amount

2

* X50@ /

X50@ Ivp X52! ]

X50@ Ivp X52! ]

X50@ Ivp X52! ]

X52! ]

Set vertical centering of the image in window X50@

to X52!.

X50@ = 0 through 4; 0 = all windows.

For X52!:

0 = 2048; limits are ± the output resolution.

Shift image in window X50@ up.

Shift image in window X50@ down.

View current setting for vertical centering of the

image in window X50@.

MGP 464 • Software Configuration and

Horizontal size (window)

Specific value

1

* X50@ * X52@ :

X50@ Whs X52@ ]

Set the width of window X50@ to X52@.

 

 

 

 

For X52@:

 

 

 

 

Minimum = 1/16 the size of the active output area.

 

 

 

 

Maximum = size of the active output area.

Increase horizontal size of window

1

* X50@ + :

X50@ Whs X52@ ]

Widen the window.

Decrease horizontal size of window

1

* X50@ – :

X50@ Whs X52@ ]

Narrow the window.

View horizontal size of window

1

* X50@ :

X52@ ]

View the width of the window.

Vertical size (window)

 

 

 

 

Specific value

1

* X50@ * X52@ ;

X50@ Wvs X52@ ]

Set the height of window X50@ to X52@.

Increase vertical size of window

1

* X50@ + ;

X50@ Wvs X52@ ]

Increase the height of the window.

Decrease vertical size of window

1

* X50@ – ;

X50@ Wvs X52@ ]

Decrease the height of the window.

View vertical size of window

1

* X50@ ;

X52@ ]

View the height of the window.

Horizontal size (image)

 

 

 

 

Specific value

2

* X50@ * X52# :

X50@ Ihs X52# ]

Set the width of the image in window X50@ to

 

 

 

 

X52#. For X52#:

Control 4-13

Increase horizontal size of image Decrease horizontal size of image

View horizontal size of image

2 * X50@ + :

2 * X50@ – :

2 * X50@ :

X50@ Ihs X52# ]

X50@ Ihs X52# ]

X52# ]

Minimum = 1/16 the size of the active input area. Maximum = double the active output area for 200% zoom.

Widen of the image.

Narrow the image.

View the width of the image.