Extron electronic MGP 464 DI Preliminary, SIS Programming and Control, cont’d, X50@ Frz, Freeze

Models: MGP 464 MGP 464 DI

1 140
Download 140 pages 21.25 Kb
Page 70
Image 70
Active lines

4-18 MGP 464 • Software Configuration and Control

PRELIMINARY

Command/response table for SIS commands (continued)

Command

ASCII (Telnet)

Response

Additional description

(host to switcher)

(switcher to host)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Active lines

 

 

 

 

 

 

 

Specific value

13 * X50) * X51& #

Aln X50) * X51& ]

Set the active lines value for the input X50) to X51&.

 

 

 

X50) = 1 through 19.

 

 

 

X51& = Auto-sensed value ± 512 lines or pixels.

Increment active lines value

13 * X50) + #

Aln X50) * X51& ]

Select the next higher active lines value.

Decrement active lines value

13 * X50) #

Aln X50) * X51& ]

Select the next lower active lines value.

View active lines setting

13 * X50) #

X51& ]

View the current active lines setting for input X50).

Output scaler rate

 

 

 

 

 

 

 

Set output resolution and scan rate

X50* * X51% =

Rte X50* * X51% ]

Select a scaler output resolution and scan rate.

 

 

 

X50* = scaler resolution. For X50*:

 

 

 

1

= 640x480

 

11 = 1366x768

 

 

 

2

= 800x600

 

12

= 1365x1024

 

 

 

3

= 852x480

 

13

= 1400x1050

 

 

 

4

= 1024x768

 

14

= 1600x1200

 

 

 

5

= 1024x852

 

15

= 480p

 

 

 

6

= 1024x1024

16

= 576p

 

 

 

7

= 1280x768

 

17

= 720p

 

 

 

8

= 1280x1024

18

= 1080i

 

 

 

9

= 1360x765

 

19

= 1080p

 

 

 

10 = 1365x768

20

= DVI background input resol.

 

 

 

X51% = scaler refresh rate. For X51%:

 

 

 

1

= 50 Hz

5 = 100 Hz

 

 

 

2

= 60 Hz

6 = 120 Hz

 

 

 

3

= 72 Hz

7 = DVI background input refresh rate

 

 

 

4

= 96 Hz

 

 

 

View output rate settings

=

X50* * X51% ]

View the current output's resolution and refresh

 

 

 

rate settings.

 

 

 

View output rate details

0 =

width * height * refresh rate ]

View the current output's size and refresh rate.

NThe output rate detail command can display the actual resolution of the output when the MGP is configured to use the DVI background rate.

SISProgramming and Control, cont’d

Freeze

Enable freeze

X50@ * 1 F

X50@ Frz 1 ]

Disable freeze

X50@ * 0 F

X50@ Frz 0 ]

View freeze status

X50@ F

X% ]

Freeze the output video image in window X50@.

X50@ = 0 through 4; 0 = all windows. Unfreeze the output image.

View the freeze status.

For X%: 1 = frozen; 0 = not frozen.

Test pattern
Page 70
Image 70
Extron electronic MGP 464 DI Preliminary, SIS Programming and Control, cont’d, X50@ Frz, Active lines, Output scaler rate