Command/response table for IP SIS commands (continued)

4-32 MGP 464 • Software Configuration

PRELIMINARY

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

(host to processor)

(host to processor)

(Processor to host)

 

 

 

 

 

 

IP setup commands (continued)

 

 

 

Set administrator password

E X3# CA }

W X3# CA

Ipa • X4! ]

Set administrator access password X3#.

 

 

 

 

X3# = 4 to 12 alphanumeric characters. The

 

 

 

 

password is case sensitive. Special characters

 

 

 

 

(spaces or symbols) are not allowed.

 

 

 

 

X4! = password displayed as four asterisks

Clear administrator password24

E • CA }

W %20 CA

Ipa • ]

(****).

Clear/remove all passwords (administrator

and user).

NA user password cannot be assigned if an administrator password does not exist. Entering a password when the MGP 464 has not been configured yields an E14 error response from the processor. If the administrator password is cleared (removed), the user password is removed also.

SISProgramming and

and

View administrator password

E CA }

W CA

X4! ]

Set user password14 24

E X3# CU }

W X3# CU

Ipu • X4! ]

View password level X4!, shown with leading zeros.

Set user password X3# (4-12 alphanumeric characters). The password is case sensitive. Special characters (spaces or symbols) are not allowed.

Control,

Control

NA user password cannot be assigned if an administrator password does not exist.

Clear user password24

E • CU }

W %20 CU

View user password

E CU }

W CU

Set extended level password24

E X5! , X3# CO }

W X5! 2%C X3# CO

Clear extended level password24

E X5! , CO }

W X5! 2%C CO

View extended level password

E X5! CO }

W X5! CO

Set read-only security level support24

E X6^ * X6* EP }

W X6^ %2A X6* EP

Ipu • ]

X4! ]

Ipo X5! X4! ]

Ipo X5! ]

X4! ]

Pvo X6^ * X6* ]

Clear the user password only.

View password level X4!, shown with leading zeros.

Set password X3# for security level X5!.

X5! = 1 through 10.

Remove password from security level X5!.

View password level X4!, shown with leading zeros.

Enable no-password login at security level

X6*.

For X6^:

0 = no-password logon disabled

1 = no-passwors logon enabled

For X6*:

0 = no-password logon is placed one level below the lowest existing password level (0 through 11).

1 through 11 = no-password logon enabled at the level specified if an admin. password exists.

cont’d

Page 84
Image 84
Extron electronic MGP 464 DI manual Control

MGP 464, MGP 464 DI specifications

Extron Electronics is renowned for its cutting-edge technology in the audiovisual industry, and the MGP 464 DI is a notable contribution to their lineup of high-performance video processing solutions. Designed to cater to a variety of applications, including corporate, educational, and event venues, the MGP 464 DI is a multifunctional multiviewer that seamlessly integrates into AV systems while delivering exceptional performance.

One of the standout features of the MGP 464 DI is its ability to support four video inputs, which can be organized into a single composite output, including HDMI and SDI options. This flexibility allows users to display multiple sources simultaneously, enhancing the visual experience for audiences. The MGP 464 DI provides configurable layouts, enabling users to customize the presentation of the input sources to meet specific needs or preferences.

The device is equipped with advanced scaling technology, ensuring that the input signals are optimally presented on a wide range of display devices. This feature not only improves image quality but also guarantees that users can present content without concerns about resolution mismatches. The MGP 464 DI supports various resolutions and formats, making it versatile and suitable for diverse applications.

Another key characteristic of the MGP 464 DI is its user-friendly interface. Featuring an intuitive on-screen menu system, operators can easily navigate through settings and configurations. Additionally, the device supports remote control capabilities, allowing for seamless operation from a distance. This functionality is particularly beneficial in environments where presentations need to be managed from a different location.

The MGP 464 DI also places a strong emphasis on robust connectivity options. With multiple HDMI Inputs and outputs, as well as SDI connections, users can easily integrate the device into existing AV systems. These options enhance flexibility and ensure the MGP 464 DI can adapt to various setups.

In terms of reliability and durability, Extron's MGP 464 DI is designed with professional-grade components, ensuring long-term performance and stability. This characteristic makes it a trustworthy choice for mission-critical environments where downtime is not an option.

In conclusion, the Extron MGP 464 DI is a powerful, versatile, and user-friendly multiviewer that excels in delivering high-quality video presentations. With its multitude of input options, advanced scaling technology, and robust connectivity, it stands as a significant asset to any professional AV setup. Whether for corporate events, educational institutions, or live broadcasts, the MGP 464 DI proves its worth as an indispensable tool in the audiovisual community.