Extron electronic MGP 464 DI SIS Programming, 6 * X50@ #, X50%, Preliminary, and Control, cont’d

Models: MGP 464 MGP 464 DI

1 140
Download 140 pages 21.25 Kb
Page 72
Image 72
4-20 MGP 464 • Software

4-20 MGP 464 • Software

PRELIMINARY

Command/response table for SIS commands (continued)

Command

ASCII (Telnet)

Response

Additional description

(host to switcher)

(switcher to host)

 

 

 

 

 

 

Query firmware version

Q

x.xx ]

View the firmware version number.

Query part number

N

60-771-01 or 60-771-02

View the MGP's part number.

View internal temperature

20S

X51( ]

View internal temperature X51( in degrees

 

 

 

Fahrenheit.

With tagged response – Verbose modes 2 and 3:

Sts20 * X51( ]

Special functions

SISProgramming

Configuration and Control

Output polarity

1 * X\ #

Example:

1

* 2 #

View output polarity

1

#

Output sync format

2

* X\ #

View output sync format

2

#

Blue mode

3

* X% #
View blue mode status

3

#

Text position

6

* X50@ * X50% #

Pol X\ ]

Pol 2 ]

X\ ]

Syn X\ ]

X\ ]

Blu X% ]

X% ]

X50@ Tlc X50% ]

Set output polarity. For X\ :

0 = H-/V- (default)

1 = H-/V+

2 = H+/V-

3 = H+/V+

H+/V– sync polarity

View the current output polarity setting.

Set the output sync format. For X\:

1 = RGBHV

2 = RGBS

3 = RGsB

4 = YUV bi-level

5 = YUV tri-level

View the current output sync format setting.

Turn blue mode on and off. For X%:

1 = blue mode on; 0 = blue mode off. View the current blue mode status.

Change the location of the text label to X50% in window X50@.

X50@ = 0 through 4; 0 = all windows.

For X50%:

0

= None

4

= Top left

1

= Bottom left

5 = Top center

2

= Bottom center

6

= Top right

3

= Bottom right

 

 

and Control, cont’d

View text position

6 * X50@ #

X50% ]

View the text label position in window X50@.

Special functions (continued)

Page 72
Image 72
Extron electronic MGP 464 DI SIS Programming, 6 * X50@ #, X50%, Preliminary, and Control, cont’d, MGP 464 Software, X% #