Extron electronic MGP 464 DI manual Preliminary, LAN port defaults, MGP 464 Installation

Models: MGP 464 MGP 464 DI

1 140
Download 140 pages 21.25 Kb
Page 23
Image 23
LAN port defaults:

Use a straight-through cable to connect to a network, or a crossover cable to connect directly to a computer.

For 10BaseT (10 Mbps) networks, use a Cat 3 or better cable.

For 100BaseT (max. 155 Mbps) networks, use a Cat 5 cable.

RJ-45 connector

Pins:

12 3 4 5 6 7 8

Side View

Insert

twisted pair wires.

Straight-through Cable

(for connection to a switch, hub, or router)

 

End 1

 

End 2

Pin

Wire Color

Pin

Wire Color

1

white-orange

1

white-orange

2

orange

2

orange

3

white-green

3

white-green

4

blue

4

blue

5

white-blue

5

white-blue

6

green

6

green

7

white-brown

7

white-brown

8

brown

8

brown

Crossover Cable

(for direct connection to a PC)

 

End 1

 

End 2

Pin

Wire Color

Pin

Wire Color

1

white-orange

1

white-green

2

orange

2

green

3

white-green

3

white-orange

4

blue

4

blue

5

white-blue

5

white-blue

6

green

6

orange

7

white-brown

7

white-brown

8

brown

8

brown

PRELIMINARY

You must also configure the LAN port before using it. You can do this by using SIS commands (see “Command/response table for SIS commands” in chapter 4, “Software Configuration and Control”) or by using the Comm./IP Configuration menu on the front panel (see “Comm./IP Configuration menu” in chapter 3, “Operation”).

LAN port defaults:

MGP’s IP address: 192.168.254.254

Gateway IP address: 0.0.0.0

Subnet mask: 255.255.0.0

DHCP: off

5Reset button — Pressing this recessed button causes various IP functions and

Ethernet connection settings to be reset to the factory defaults.

6Reset LED This green LED, located to the upper-right of the reset button, blinks a varying number of times to indicate which reset mode has been entered. See “Resetting the unit” in chapter 3, “Operation,” for details.

MGP 464 • Installation 2-7

Page 23
Image 23