X1$ =

Local output sync polarity

0

= H- / V- (default)

 

 

 

1

= H+ / V-

 

 

 

2

= H- / V+

 

 

 

3

= H+ / V+

 

 

 

4

= No sync stripping (composite, S-video, YUV)

X1%

=

Local audio output number

1

– 4 (matrix sizes 1616 and smaller)

 

 

 

1

– 8 (matrix sizes 1632 and larger)

X1^ =

Volume adjustment range

0

– 64 (1 dB/step except for 0-to-1, which is 22 dB)

 

 

 

(default = 64 [0 dB])

 

 

 

(See the table on page 4-14.)

X1& =

Audio gain

0

– 24 (1 dB/step)

X1*

=

Numeric dB value

–18 to +24 (45 steps of gain or attenuation) (Default = 0 dB)

X1( =

Audio attenuation

1

– 18 (1 dB/step)

X2)

=

Global or room preset #

0

- 32, 10 maximum for a room preset (0 = current configuration)

N A Room preset is a stored configuration with all of the outputs assigned to a single room. When a room preset is retrieved from memory, it becomes the current configuration.

X2! = Name

12 characters maximum for input, output, and global preset names

 

Upper- and lower-case alphanumeric characters and

 

_ / and spaces are valid.

NThe following characters are invalid in the name: {space} ~ , @ = ‘ [ ] { } < > ’ “ ; : \ and ?.

X2@ = Room # (for room presets)

10 max. (each can have up to 10 presets (X2)s) assigned)

N A Room is a subset of operator-selected outputs that relate to each other. The MTPX Plus switchers support up to 10 rooms, each of

which can consist of from 1 to 16 outputs.

X2# = Group # (for I/O grouping)

X2$ = Audio or RS-232 mute:

1 through 4 groups (0 = no group)

0 = no mutes

2 = audio or RS-232 mute

X2%

=

Local input select DIP switch status

0 = RJ-45 position, 1 = local input position

X2^ =

Number of inputs

8, 16, or 32

X2& =

Number of outputs

8, 16, or 32

X2*

=

Part number

60-nnn-nn

X2( =

Firmware version number to second decimal place (x.xx)

 

X3)

=

Verbose firmware version-description-upload date/time.

 

 

 

See the Query firmware version (verbose) command on page 4-22.

X3! =

Voltage

Positive or negative voltage and magnitude

X3@ =

Internal temperature

Degrees Fahrenheit

X3# =

Fan speed

RPM

MTPX Plus Twisted Pair Matrix Switchers • Programmer’s Guide

4-9

Page 103
Image 103
Extron electronic MTPX Plus Series manual X2 =, X3! =, X1$ =, X3# =