Extron electronic MTPX Plus Series manual Command/response table for IP-specific SIS commands

Models: MTPX Plus Series

1 190
Download 190 pages 3.12 Kb
Page 119
Image 119
Command/response table for IP-specific SIS commands

Command/response table for IP-specific SIS commands

Command

ASCII command

Response

Additional

 

(host to switcher)

(switcher to host)

description

IP setup commands

 

 

 

Set matrix name

EX4)CN}

Ipn•X4)]

 

Read matrix name (location

ECN}

X4)]

 

Reset matrix name to

E•CN}

Ipn•X4)]

 

factory default

 

 

 

Set time and date

EX4@CT}

IptX4@]

 

Read time and date

ECT}

X4#]

 

Set GMT offset

EX4$CZ}

IpzX4$]

In the command, the divider

 

 

 

between hours and minutes

 

 

 

can be either a colon or a

 

 

 

period. In the response, the

 

 

 

divider is a colon.

Example: Read GMT offset

Set Daylight Savings Time Read Daylight Savings Time Set IP address

Read IP address

Read hardware address Read # of open connections Set subnet mask

Read subnet mask

Set gateway IP address Read gateway IP address Set administrator password

Read administrator password

Reset (clear) administrator password

Set user password Read user password Reset (clear) user password

Set mail server, domainname Read mail server, domainname

Set e-mail recipient

E8.0CZ}

 

 

Ipz+08:00]

 

 

8.3 = 8:30

ECZ}

 

 

 

X4$]

 

 

 

 

 

EX4%CX}

 

 

X4%]

 

 

 

 

 

ECX}

 

 

 

X4%]

 

 

 

 

 

EX4^CI}

 

 

IpiX4^]

 

 

 

ECI}

 

 

 

X4^]

 

 

 

 

 

ECH}

 

 

 

X4&]

 

 

 

 

Reads MAC address.

ECC}

 

 

 

X4*]

 

 

 

 

 

EX4^CS}

 

 

IpsX4^]

 

 

 

ECS}

 

 

 

X4^]

 

 

 

 

 

EX4^CG}

 

 

IpgX4^]

 

 

 

ECG}

 

 

 

X4^]

 

 

 

 

 

EX4(CA}

 

 

Ipa•X4(]

 

 

 

ECA}

 

 

 

X4(]

 

 

 

 

 

E•CA}

 

 

 

Ipa•]

 

 

 

 

 

EX4(CU}

 

 

Ipu•X4(]

 

 

 

ECU}

 

 

 

X4(]

 

 

 

 

 

E•CU}

 

 

 

Ipu•]

 

 

 

 

 

EX4^

,

X5)

X4(

CM

}

Ipm

X4^

,

X5)

,

X4(]

 

 

 

,

 

 

 

 

 

ECM}

 

 

 

X4^,X5),X4(]

 

EX5!,X5@CR}

 

IprX5!,X5@,]

This command sets the

 

 

 

 

 

 

 

 

 

 

 

 

recipient. To receive e-mail

notifications, you must then set the events that the switcher reports, using one or more separate Set e-mail events (EM) commands (see next page).

Example:

E72,Jsmith@folklore.netCR}

 

EX5!CR}

Ipr72,Jsmith@folklore.net,]

Read e-mail recipient

X5@,]

MTPX Plus Twisted Pair Matrix Switchers • Programmer’s Guide 4-25