Extron electronic MTPX Plus Series Programmer’s Guide, cont’d, Command, ASCII command, Response

Models: MTPX Plus Series

1 190
Download 190 pages 3.12 Kb
Page 116
Image 116
Information requests

Programmer’s Guide, cont’d

Command/response table for SIS commands (continued)

Command

ASCII command

Response

Additional

 

(host to switcher)

(switcher to host)

description

Information requests

 

 

 

Information request

I

VX2^XX2&•AX2^XX2&]

V (video) matrix size•

 

 

 

A (audio) matrix size

Request part number

N

X2*]

See appendix B for part

 

 

 

numbers.

NThere are up to three separate sets of Extron firmware on which the switcher can report: the controller firmware, which is the overall control firmware; the Ethernet protocol firmware, which handles the Ethernet interface; and the latest optional Extron firmware update, which is available at www.extron.com.

Query controller firmware

Q

X2(]

 

 

 

version

 

 

 

 

 

 

 

 

Example:

Q

1.23]

 

The factory-installed

 

 

 

 

 

 

 

 

 

 

controller firmware version

 

 

 

 

 

 

 

 

 

 

is 1.23 (sample value only).

Query controller firmware

0Q

X2(-X3)-X3)]

Provide a detailed status of

version (verbose)

 

 

 

 

 

the MTPX Plus controller

 

 

 

 

 

 

 

 

 

 

firmware and any firmware

 

 

 

 

 

 

 

 

 

 

upgrade. The firmware that

 

 

 

 

 

 

 

 

 

 

is running is marked by

 

 

 

 

 

 

 

 

 

 

an asterisk (*). A caret (^)

 

 

 

 

 

 

 

 

 

 

indicates that the firmware

 

 

 

 

 

 

 

 

 

 

has a bad checksum or an

 

 

 

 

 

 

 

 

 

 

invalid load. ?.?? indicates

 

 

 

 

 

 

 

 

 

 

that firmware is not loaded.

Response description: Ethernet protocol firmware version-controller firmware version-updated firmware version]

Example:

0q

 

 

 

 

 

 

 

 

 

 

Description

 

* indicates the version running

Upload date and time

 

 

 

 

 

 

 

1.23-1.00(1.06-16x16 Series -Tue, 04 Dec 2007 00:00:00 GMT)-1.00*(1.06-16x16 Series

-Thu, 27 Dec 2006 16:39:21 GMT)

 

 

 

 

 

 

 

 

 

 

 

 

Ethernet protocol

 

 

 

MTPX firmware version

 

 

 

Updated firmware version

firmware

 

 

 

 

 

 

 

 

Request system status

S

X3!X3!X3!X3!X3!X3@X3#X3#]

Response description: +3.3V+5V-5V+12V-12Vtemperature (degrees fahrenheit)Fan 1 speedFan 2 speedFan 3 speed]

NFans are numbered 1, 2, and 3, from rear to front.

Example:

 

 

 

+12V power system at 11.62V

 

 

 

 

 

 

 

 

 

3.28•+4.98•-5.01•+11.52•-12.35•+086.80•03590•03668•03627

 

 

 

 

3.3V power system at 3.28V

 

 

 

 

 

Fan 1 (rear) rotating at 3590 RPM

 

 

 

 

 

 

 

N X2^= Number of inputs

8, 16, or 32

 

 

X2&= Number of outputs

8, 16, or 32

 

 

X2*

= Part number

60-nnn-nn

 

 

X2(= Firmware version number to second decimal place (x.xx)

 

 

X3)

= Verbose firmware version-description-upload date/time

 

 

X3!= Voltage

Positive or negative voltage and magnitude

X3@= Temperature

Degrees Fahrenheit

 

 

X3#= Fan speed

RPM

 

 

4-22 MTPX Plus Twisted Pair Matrix Switchers • Programmer’s Guide