Programmer’s Guide, cont’d

Command/response table for SIS commands (continued)

Command

ASCII command

Response

Additional

 

(host to switcher)

(switcher to host)

description

Input skew adjustment

 

 

 

Set all input skew

EX#*X(*X(*X(Iseq}

 

adjustment values

 

IseqX#*X(*X(*X(]

Example:

E2*0*0*4Iseq}

Iseq02*00*00*04]

Increment one input skew

EX#*X1)+Iseq}

IseqX#*X(*X(*X(]

adjustment value

 

 

Example:

E2*2*+Iseq}

Iseq02*00*00*05]

Decrement one input skew

EX#*X1)-Iseq}

IseqX#*X(*X(*X(]

adjustment value

 

 

Read input skew

EX#Iseq}

X(*X(*X(]

adjustment values

 

 

Set a specific skew adjustment for the TP input. X(values are listed in RGB order.

Set input 2’s skew settings as follows:

Red = 0 ns Green = 0 ns

Blue = 8 ns (delayed 8 ns).

Increase input X#’s X1) plane’s skew adjustment by 1 step (2 ns).

Increase input 2’s blue skew by 2 ns to 10 ns.

Decrease input X#’s X1) plane’s skew adjustment by 1 step (2 ns).

Output pre-peaking

Set output pre-peaking on

EX1!*1Opek}

 

OpekX1!*1]

Pre-peak the TP output.

Set output pre-peaking off

EX1!*0Opek}

 

OpekX1!*0]

Do not pre-peak the TP

 

 

 

 

output.

Read output pre-peaking

EX1!Opek}

 

X1@]

 

setting

 

 

 

 

 

 

 

N X#= Input number

 

01 – (maximum number of inputs for your model)

X&= Input signal level/peaking range

000 – 255

 

X(= Skew adjustment range

00 – 31 (each step = 2ns)

 

X1)= Video plane

 

0

= red

 

 

 

1

= green

 

X1!= Pre-peakable output number

2

= blue

 

MTPX Plus 168

01 – 04

 

 

MTPX Plus 816, 1616, 3216

01 – 08

X1@= Pre-peaking

 

MTPX Plus 1632, 3232

01 – 16

 

0

= off

 

 

 

1

= on

 

4-12 MTPX Plus Twisted Pair Matrix Switchers • Programmer’s Guide

Page 106
Image 106
Extron electronic MTPX Plus Series manual EX#*X*X*XIseq, EX#*X1+Iseq IseqX#*X*X*X, EX#*X1-Iseq IseqX#*X*X*X, EX#Iseq