Introduction, cont’d
Twisted pair (TP) cable advantages
Twisted pair cable is much smaller, lighter, more flexible, and less expensive than coaxial cable. These TP products make cable runs simpler and less cumbersome. Termination of the cable with
CDo not connect this device to a computer data or telecommunications network.
Transmission distances
The maximum distances are determined by the frequency and resolution of the video signal being routed and by which MTPX Plus inputs and outputs (TP or local) are in the full (video source to display) routing path. The tables below and on the next page specify the recommended maximum transmission distances using Extron Enhanced
N• For both tables, the minimum TP cable length should be 50’ (15 m).
•
•It is possible to exceed the recommended distances; however, image quality may be reduced.
•For both tables, the MTPX output can be extended by 50’ (15 m) for those outputs (MTP transmitter or MTPX) that have a
•The transmitters, receivers, and matrix switcher are designed for and perform best with Extron Enhanced
•The recommendations shown in the tables apply equally for a transmission line consisting of a single transmitter, the switcher, and receiver and for a transmission line that encompasses a transmission daisy chain. For example, the maximum suggested output range (MTPX Plus TP output to MTP receiver) for 1024 x 768 video is 450’ (135 m), whether the transmission line consists of the switcher and a single receiver or the switcher and three daisy- chained receivers. This range can be extended to 500’ if the output is one that has the
•For
(15 m) from the switcher when the
•For