Operation, cont’d

Performing soft system resets (resets 3, 4, and 5)

Perform a soft reset of the switcher as follows:

1.

Use an Extron Tweeker or other small screwdriver to press and hold the rear

 

panel Reset button until the front panel Video and Audio buttons blink the

 

number of times for the desired reset: once (events reset), twice (system reset),

 

or three times (absolute reset) (figure 3-76).

Press and hold the Reset button.

(Mode 1)

RESET

Events Reset

 

Reset LED flashes once.

3 seconds

RESET

 

Release, then immediately press and release again.

RESET

Front panel I/O buttons flash once.

I / O

VIDEO

AUDIO

Press and hold

Reset LED flashes twice.

the Reset button.

IP Settings

RESET

6 seconds

RESET

 

 

Reset

 

 

 

(Mode 4)

 

 

 

Release, then immediately press and release again.

RESET

Front panel I/O buttons flash twice.

I / O

VIDEO

AUDIO

Press and hold the Reset button.

(Mode 5)

RESET

Absolute Reset

 

Reset LED flashes

three times.

9 seconds

RESET

 

Release, then immediately press and release again.

RESET

Front panel I/O buttons flash three times.

I / O

VIDEO

AUDIO

Figure 3-76 — Soft system resets

2. Release the Reset button and then immediately press and release the Reset button again. Nothing happens if the second momentary press does not occur within 1 second.