3. To change an input’s audio/RS-232 wire pair configuration, press and release the input button to toggle that input’s configuration (figure 3-70).

Press and release the Input 8 button to toggle the configuration of input 8’s audio/RS-232 wire pair (to audio, in this example).

INPUTS

1 2 3 4 5 6 7 8 9 16

Figure 3-70Audio/RS-232 selection

4.

Press and release an output button to exit the Serial Port and Audio/RS-232

 

Input Configuration mode (figure 3-71).

 

 

 

 

Press and release

All Control, I/O, Input, and Output buttons

 

return to unlit or background illumination.

 

an output button.

 

 

 

 

 

 

 

 

C O N T R O L

 

I / O

 

 

 

 

 

 

 

 

 

 

 

 

 

5

ENTER

PRESET

VIEW

ESC

VIDEO

AUDIO

 

 

 

 

 

 

 

 

Figure 3-71 — Exit Serial Port and Audio/RS-232 Input Configuration mode

Selecting the rear panel Remote port protocol and baud rate

NThe Remote port settings are protected when front panel Lock mode 2 is selected. You can view the settings in Lock mode 2 but you cannot adjust them from the front panel. See “Setting the front panel Locks (Executive modes)” on page 3-46.

The switcher can support either RS-232 or RS-422 serial communication protocol,

and can operate at 9600, 19200, 38400, and 115200 baud rates. The settings of these variables can be viewed and changed from the front panel.

View and configure the switcher’s serial communications settings as follows:

1.

To enter Serial Port and Audio/RS-232 Input Configuration mode, simultaneously

 

press and hold all Control buttons (Enter, Preset, View, and Esc) (figure 3-72).

Press and hold the Enter, Preset,

View, and Esc buttons.

C O N T R O L

C O N T R O L

 

I / O

ENTER

PRESET

VIEW

ESC

2 seconds

 

VIEW

ESC

 

 

ENTER

PRESET

VIDEO

AUDIO

 

 

 

 

NOTE The Input buttons indicate the configuration of the secondary wire pairs. See “Selecting the TP wire pair secondary input”, earlier in this chapter.

All Control buttons light with

Both I/O buttons light

one flashing.

with one flashing.

The flashing Control button indicates the baud rate as follows:

Enter — 9600

Preset — 19200

View — 38400

Esc — 115200

The flashing I/O button indicates the protocol as follows:

Video — RS-232

Audio — RS-422/RS-485

In this example, the port is set to RS-232 at 9600 baud.

Figure 3-72RS-232/RS-422 and baud rate display