7. The switcher checks several possibilities, in the following order, and then responds accordingly:

a. Does the address include a specific file name, such as 10.13.156.10/file_name.html? If so, the switcher downloads that HTML page.

b. Is there a file in the switcher’s memory that is named “index.html”?

If so, the switcher downloads “index.html” as the default startup page.

c. If neither of the above conditions is true, the switcher downloads the factory-installed default startup page, “nortxe_index.html” (figure 6-2),also known as the System Status page.

System Status Page

The System Status page (figure 6-2) provides an overall view of the status of the matrix switcher, including individual voltages, and the serial port status. The System Status page is the default page that the switcher downloads when you connect to the switcher. Access the System Status page from other pages by clicking the Status tab.

Refresh

Figure 6-2 System Status page

The status web page periodically updates itself to reflect the latest status of the switcher components. If a value changes, the display shows the change in status the next time it updates.

MTPX Plus Twisted Pair Matrix Switchers • HTML Operation