2620A/2625A

Users Manual

ASCII & BUS CODES

B7

B6

 

 

 

0

0

 

0

0

 

 

0

0

 

 

0

0

 

 

0

1

 

 

0

1

 

 

0

1

 

 

0

1

27

 

 

5

 

 

0 0

 

0 1

 

1 0

 

1 1

 

0 0

 

0 1

 

1 0

 

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

B

 

B4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11 224

BITS

 

 

CONTROL

 

NUMBERS

 

UPPER CASE LOWER CASE

B3

B2 B1

B0

 

 

SYMBOLS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

0

16

 

 

 

10

32

 

 

20

48

 

 

 

30

64

 

 

40

80

 

 

50

96

 

60

112

70

0

0

0

0

 

NUL

 

 

 

 

 

 

SP

 

 

0

 

 

@

 

 

P

 

 

 

 

 

 

 

p

 

 

 

 

 

NUL

 

DLE

 

 

SPACE MLA0 0

 

 

MLA16

@

 

MTA0

P

 

MTA16

 

 

MSA0

P

 

MSA16

0

0

0

1

1

 

 

1

17

 

 

 

11

33

 

!

21

49

 

1

31

65

A

41

81

Q

51

97

a

61

113

71

SOH

GTL

 

 

 

 

 

 

 

 

1

 

 

 

A

 

Q

 

a

 

 

q

q

 

 

 

 

 

DC1

 

 

!

 

MLA1

 

 

MLA17

 

MTA1

 

MTA17

 

MSA1

MSA17

0

0

1

0

2

 

 

2

18

 

 

12

34

"

22

50

 

 

2

32

66

 

B

42

82

R

52

98

b

62

114

72

STX

 

 

 

 

 

 

"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

r

 

 

 

 

 

 

DC2

 

 

 

MLA2

2

 

 

MLA18

B

 

MTA2

R

 

MTA18

b

 

MSA2

r

MSA18

0

0

1

1

3

 

 

3

19

 

 

13

35

#

23

51

 

 

3

33

67

 

C

43

83

S

53

99

c

63

115

73

ETX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

s

 

 

 

 

 

 

DC3

 

 

#

 

MLA3

3

 

 

MLA19

C

 

MTA3

S

 

MTA19

c

 

MSA3

s

 

MSA19

0

1

0

0

4

 

 

4

20

 

 

14

36

$

24

52

 

4

34

68

D

44

84

T

54

100

d

64

116

74

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t

 

 

 

 

 

EOT

SDC

DC4

DCL

$

 

MLA4

4

 

 

MLA20

D

 

MTA4

T

MTA20

d

 

MSA4

t

 

MSA20

 

 

 

 

 

5

 

 

5

21

 

 

 

15

37

%

25

53

 

5

35

69

E

45

85

U

55

101

e

65

117

75

0

1

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

u

 

 

 

 

 

ENQ

PPC

NAK

PPU

%

 

MLA5

5

 

 

MLA21

E

 

MTA5

U

MTA21

e

 

MSA5

u

MSA21

0

1

1

0

6

 

 

6

22

 

 

16

38

&

26

54

 

6

36

70

F

46

86

V

56

102

f

66

118

76

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

v

 

 

 

 

 

ACK

 

SYN

 

 

&

 

MLA6

6

 

 

MLA22

F

 

MTA6

V

MTA22

f

 

MSA6

v

 

MSA22

0

1

1

1

7

 

 

7

23

 

 

17

39

 

'

27

55

 

7

37

71

G

47

87

W

57

103

g

67

119

77

 

BEL

ETB

 

 

'

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

w

 

 

 

 

 

BEL

 

 

 

 

MLA7

 

 

MLA23

G

 

MTA7

W

MTA23

g

 

MSA7

w

MSA23

1

0

0

0

8

 

 

8

24

 

 

18

40

(

28

56

 

8

38

72

H

48

88

X

58

104

h

68

120

78

 

 

BS

 

 

 

 

 

(

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x

 

 

 

 

 

BS

GET

CAN

SPE

 

MLA8

8

 

 

MLA24

H

 

MTA8

X

MTA24

h

 

MSA8

x

 

MSA24

1

0

0

1

9

 

 

9

25

 

 

19

41

)

29

57

 

9

39

73

 

I

49

89

Y

59

105

i

69

121

79

 

 

HT

 

 

 

 

 

)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

y

 

 

 

 

 

HT

TCT

EM

 

SPD

 

MLA9

9

 

 

MLA25

I

 

MTA9

Y

MTA25

i

 

MSA9

y

 

MSA25

 

 

 

 

 

10

 

A

26

 

 

1A

42

*

2A

58

 

:

3A

74

 

 

4A

90

Z

5A

106

 

6A

122

7A

1

0

1

0

 

 

LF

 

 

 

 

 

*

 

:

 

 

 

 

J

 

 

 

 

 

j

 

 

 

z

 

 

 

 

 

LF

 

 

SUB

 

 

 

MLA10

 

 

MLA26

J

 

MTA10

Z

MTA26

j

 

MSA10

z

 

MSA26

1

0

1

1

11

 

B

27

 

 

1B

43

+

2B

59

 

;

3B

75

K

4B

91

 

[

5B

107

k

6B

123

7B

 

 

VT

ESC

+

 

;

 

 

 

 

 

 

 

 

 

 

 

 

 

{

 

 

 

 

 

VT

 

 

ESC

 

 

 

MLA11

 

 

MLA27

J

 

MTA11

[

MTA27

k

 

MSA11

{

 

MSA27

1

1

0

0

12

 

C

28

 

 

1C

44

,

2C

60

 

<

3C

76

L

4C

92

 

\

5C

108

6C

124

7C

 

 

FF

 

 

 

 

 

,

 

<

 

 

 

 

 

 

 

 

 

 

 

 

 

:

 

 

 

 

 

FF

 

 

FS

 

 

 

 

MLA12

 

 

MLA28

L

 

MTA12

\

MTA28

 

MSA12

:

 

MSA28

1

1

0

1

13

 

D

29

 

 

1D

45

 

-

2D

61

 

 

3D

77

M

4D

93

 

]

5D

109

m

6D

125

7D

 

 

CR

GS

 

 

 

-

 

 

 

 

 

MLA29

 

 

 

 

 

 

 

 

 

 

}

 

 

 

 

 

CR

 

 

 

 

 

MLA13

 

 

 

M

 

MTA13

]

MTA29

m

MSA13

}

 

MSA29

1

1

1

0

14

SO E

30

 

 

1E

46

 

. 2E

62

 

>

3E

78

N

4E

94

^

5E

110

n

6E

126 ~ 7E

 

 

 

 

 

SO

 

RS

 

 

 

.

 

MLA14

>

 

 

MLA30

N

 

MTA14 ^

MTA30

n

 

MSA14

~

MSA30

1

1

1

1

15

 

F

31

~

1F

47

 

/

2F

63

 

 

3F

79

O

4F

95

_

5F

111

 

6F

127

7F

 

 

SI

 

 

 

/

 

 

?

 

 

?

 

 

 

_

 

 

 

o

 

RUB-

 

 

 

 

 

SI

 

 

US

 

 

 

 

MLA15

 

 

UNL

O

 

MTA15

 

UNT

o

 

MSA15 OUT MSA31

2 3

2 2 2 1

20

ADDRESSED UNIVERSAL

 

 

 

LISTEN

 

 

 

 

 

 

TALK

 

 

 

SECONDARY ADDRESSES

 

 

 

 

 

COMMANDS COMMANDS

 

 

ADDRESSES

 

 

 

ADDRESSES

 

 

 

OR COMMANDS

 

 

 

 

 

 

 

 

KEY

decimal

38

 

 

26

hex

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1722A DISPLAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

&

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

&

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ASCII

 

 

MLA6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

oo25f.eps

B-2

Page 170
Image 170
Fluke 2625A, 2620A user manual Key

2625A, 2620A specifications

The Fluke 2625A is a sophisticated data logger designed for a wide range of industrial and laboratory applications. This versatile instrument excels in capturing and monitoring temperature and voltage measurements with precision and reliability. One of its standout features is its ability to record data from various sensors, making it ideal for environments where comprehensive data acquisition is critical.

Equipped with a large LCD display, the Fluke 2625A provides clear and user-friendly access to real-time measurement data. Its graphical interface allows users to visualize trends and monitor readings easily, which significantly enhances usability. The device supports a variety of input types and can connect to thermocouples, RTDs, and other sensors, offering great flexibility for various measurement tasks.

The Fluke 2625A employs advanced measurement technologies that ensure accuracy in data logging. With a high sampling rate, it captures fast-changing signals while maintaining data integrity. The device features a built-in memory that allows for extensive logging, accommodating long-term monitoring tasks without requiring constant oversight. Users can set it to log data at specified intervals, offering customizable solutions for different monitoring needs.

Another significant characteristic of the Fluke 2625A is its robust communication capabilities. The device supports USB and RS-232 interfaces for easy connectivity with computers and other devices, making data transfer and analysis seamless. This feature is especially beneficial for users who need to compile or analyze large sets of data quickly.

Furthermore, the Fluke 2625A is designed with durability in mind. Its rugged construction makes it suitable for challenging environments, including those with high levels of vibration, dust, or moisture. This reliability ensures that the device can withstand the rigors of fieldwork while still delivering accurate measurements.

In summary, the Fluke 2625A is a powerful data logger that combines versatility, accuracy, and reliability. Its user-friendly interface, advanced measurement technologies, and robust design make it an essential tool for professionals in various industries, from manufacturing and HVAC to research and development. Whether monitoring temperature changes in a laboratory or assessing voltage levels in an industrial setting, the Fluke 2625A stands out as a trusted solution for effective data logging and analysis.