NOTE: If you take longer than three minutes to plug the Network Cable in from the second amplifier (Step 15) the SXRC will time out and return to the scrolling Default Menu. If this happens you will then need to skip Step 16 and return to the Autosearch Menu by following Steps 17-19.

Like before, the SXRC will ask if you want to save the current settings of your second amplifier

into a memory preset. Use the UP or DOWN

 

 

keys to select SAVE - YES or SAVE - NO and

ESC

HOME ENT

press the ENT key to select.

 

 

Installation

Step 16.) If the ISIS Display is showing AUTOSEARCH press the ENT key to detect, update and load the second amplifier. Skip to Step 20.

Step 17.) Press the ENT key one time to enter the SXRC Main Menu. The first Main Menu item will be displayed which is AMP ADJ.

ESC

ESC

HOME

ENT

HOME

ENT

If you select SAVE - NO then the amplifier’s current settings are not stored into the SXRC.

NOTE:

The memory settings in the SXRC are a global memory system. What this means is that each memory preset (1-4) stores the settings of all (up to 16) the amplifiers connected to it. This allows you to have unique settings for each amplifier stored and

Step 18.) Press the UP or DOWN key until the display reads SXRC SETUP . Press the ENT key to enter the SXRC SETUP Menu.

Step 19.) Press the UP or DOWN key until the display reads AUTOSearch . Press the ENT key to activate the AUTOSEARCH function.

ESC HOME ENT

ESC HOME ENT

ready for instant recall. If you chose Memory-1before, you can choose it again. All amplifiers will have their individual settings stored here in memory location 1 for instant recall later.

If you select SAVE - YES then you choose which Global

Memory Location to store the amplifier’s settings in by using the

UP or DOWN key to scroll through the options

Step 20.) The SXRC is now searching for the second amplifier connected to the Communications Network. It will do the exact same sequence (A-P) as in step 13. Once it detects the amplifier it will load the new software into the amplifier and verify the software upload has been successful. The remote will then display how many amplifiers have been detected (2 at this point), successfully updated and brought into the SXRC Communications Network.

AMP1 AMP2

LOCK LEFT SYS RIGHT MUTE GAIN EQ LPF HPF PHASE KOMP

s eaarrcch *

MEM-1 MEM-2 MEM-3 MEM-4

AMP1 AMP2

LOCK LEFT SYS RIGHT MUTE GAIN EQ LPF HPF PHASE KOMP

p rooggrraamm==0 0

MEM-1 MEM-2 MEM-3 MEM-4

AMP1 AMP2

LOCK LEFT SYS RIGHT MUTE GAIN EQ LPF HPF PHASE KOMP

v erriiffy =0 0

MEM-1 MEM-2 MEM-3 MEM-4

AMP1 AMP2

LOCK LEFT SYS RIGHT MUTE GAIN EQ LPF HPF PHASE KOMP

2 unniitts

(Memory-1through Memory-4). When the memory

 

 

you want to use is selected press the ENT key to

ESC HOME

ENT

 

 

store. The SXRC will respond by blinking STORED to confirm the memory storing has completed successfully.

The display will then read AUTOSEARCH which indicates the software update process has completed.

MEM-1 MEM-2 MEM-3 MEM-4

20

SXRC Remote Control

Page 20
Image 20