Operation

1.) Use the UP or DOWN arrow keys to select the model of amplifier you are loading software into. You MUST select the correct one for the software load to work. MONO SW (SX.1 Series)

QUADRO SW (SX.4 Series)

STEREO SW (SX.2 Series)

2.) Press the ENT key to start the loading process.

ESC HOME ENT

ESC HOME ENT

The SXRC will display UPDATED OK to

LOCK LEFT

SYS RIGHT

MUTE

 

AMP1

 

AMP2

verify the software loading process

GAIN EQ LPF HPF PHASE KOMP

u pddaatteed

o k

has completed successfully.

MEM-1 MEM-2 MEM-3

MEM-4

3.) Press the ENT or ESC key to return to

 

 

the SW UPDATE menu.

ESC

HOME

ENT

You can load another amplifier with software by following the process outlined above.

The display will say DETECT LDR. You now have 10 seconds to power up the amplifier.

If you do not power up the amplifier

AMP1 AMP2

LOCK LEFT SYS RIGHT MUTE GAIN EQ LPF HPF PHASE KOMP

d e t ect ld r

MEM-1 MEM-2 MEM-3 MEM-4

AMP1 AMP2

If you are done manually loading software into SX Series amplifiers you can remove the jumper wire from the SXRC Interface Box and re-connect the Remote Turn-On wire.

Communication

Interface Box Network Jack (RJ45)

within 10 seconds of activating the software loading process it will time out and display FAILED in the display.

LOCK LEFT SYS RIGHT MUTE GAIN EQ LPF HPF PHASE KOMP

f aiilleed

MEM-1 MEM-2 MEM-3 MEM-4

SXRC TO

 

 

 

 

 

FROM AMP

+1

RE

M

G

ND

 

 

Power, Ground

Remote Jack

 

 

Ground

 

 

HyperFlex

 

 

 

 

 

 

 

Remote

 

HyperFlex

 

 

 

 

 

HyperFlex

5

+12 Volt

If it FAILED then turn off your SX Series

 

amplifier and press the ENT key to

ESC HOME ENT

return to Step 1 and try again.

 

Network Cable

Fuse

AMP STRAPPING

When done correctly the SXRC will recognize the amplifier and begin the software loading process.

A AMP1 AMP2

LOCK LEFT SYS RIGHT MUTE GAIN EQ LPF HPF PHASE KOMP

e raassiinng

*

MEM-1 MEM-2 MEM-3

MEM-4

B AMP1AMP2

IN OUT

NOTE:

IN OUT

LOCK LEFT SYS RIGHT MUTE GAIN EQ LPF HPF PHASE KOMP

Just a reminder that the SX Series amplifier must be off

»A.) Erase old software...

 

p rooggrraamm==0 0

»B.) Load new software...

 

MEM-1

MEM-2 MEM-3 MEM-4

»C.) Verify software is good...

C

GAIN EQ LPF HPF PHASE KOMP

 

AMP1

AMP2

 

LOCK

LEFT SYS RIGHT MUTE

v erriiffy =0 0

MEM-1 MEM-2 MEM-3 MEM-4

BEFORE you start the software loading process. You turn on the amplifier only after the SXRC ISIS display shows DETECT LDR.

74

SXRC Remote Control

Page 74
Image 74
Fortinet 2 SXRC manual Aiilleed, Erriiffy =0