Fortinet 2 SXRC manual Menu and choose another function to adjust

Models: 2 SXRC

1 88
Download 88 pages 58.82 Kb
Page 33
Image 33
1119 hz
AMP1AMP2
LOCK LEFT SYS RIGHT MUTE GAIN EQ LPF HPF PHASE KOMP

hi-passMENU - Here is where you adjust the selected amplifier’s high pass crossover.

Use the UP and DOWN keys to scroll through frequency and slope and then

press the ENT key to select.

ESC HOME

ENT

 

 

When you are done adjusting the high pass

 

 

crossover on this amplifier press the

 

 

ESC key while in the frequency and

ESC

HOME ENT

slope options menu to return to the AMP ADJ

 

 

menu and choose another function to adjust.

 

 

FREQUENCY selects the crossover point and can be set at any 1/12th octave spaced frequency from 10 Hz to 16 kHz.

(10 Hz to 16132 Hz) SX.1 Series is 10 Hz to 159 Hz in 1 Hz steps.

NOTE:

While you are in the HI-PASS menu the HPF indicator on the ISIS display is lit. This indicates you are making adjustments in the HI-PASS menu.

AMP1 AMP2

LOCK LEFT SYS RIGHT MUTE GAIN EQ LPF HPF PHASE KOMP

s lope

MEM-1 MEM-2 MEM-3 MEM-4

Operation

Use the UP and DOWN keys to select your

 

 

frequency. Press the ESC key to save your

 

 

setting and return to the frequency and

 

 

slope options menu. You can now select

ESC

HOME ENT

another high pass crossover option to adjust

 

 

on this amplifier if desired.

 

 

The KICKER SXRC monitors and prevents any high pass crossover point from being set any closer than 1/3 octave from the low pass crossover point. If you cannot set the high pass crossover where you want then check the ISIS display and see if the HPF is lit and the LPF indicator is flashing. If it is then you need to go to the

SLOPE selects the roll-off of the crossover and can be set from oFF to 36 dB/OCT in 6 dB steps. SX.1 Series is OFF to

LO-PASS menu and raise the low pass crossover point.

MEM-1 MEM-2 MEM-3 MEM-4

24 dB in 6 dB Steps.

Use the UP and DOWN keys to select your

 

 

high pass crossover slope. Press the ESC

 

 

key to save your setting and return to the

 

 

frequency and slope options menu. You

ESC

HOME ENT

can now select another high pass crossover

 

 

option to adjust on this amplifier if desired.

 

 

This is done as a safety precaution to prevent a notch filter condition.

SXRC Remote Control

33

Page 33
Image 33
Fortinet 2 SXRC manual Menu and choose another function to adjust, LO-PASS menu and raise the low pass crossover point