NOTE:

If steps 21-27 worked correctly, you should now have three SX

Step 28.) If you are only controlling only three

Communication

Interface Box Network Jack (RJ45)

Series amplifiers updated and brought into the SXRC Communications Network, skip to step 30. If not, then read on.

If the display came back blinking 2 Units after doing the AUTOSEARCH then there is a problem with the Communications Network.

SX Series amplifiers with the SXRC (Only 3? You probably have three just on bass duty!) you can skip to the next section in the manual titled Operation. If you have

SXRC TO

 

 

 

 

 

 

 

 

V

RE

M

 

ND

FROM AMP

+

12

 

G

 

5-Meter Network Cable

Power, Ground

Remote Jack

 

 

 

Ground

 

 

 

HyperFlex

 

 

 

 

 

 

 

 

 

 

Remote

 

 

HyperFlex

 

 

 

 

 

 

5

+12 Volt

 

 

HyperFlex

 

Fuse

AMP STRAPPING

• Go back and double check your Communication Network

cable between the second and third amplifier and make sure it is

inserted properly and ‘snapped’ into place.

more than three SX Series amplifiers to control then continue with Step 29.

IN OUT

IN OUT

1-Meter Network Cable

Installation

• If you have purchased different cables, double check that they

Step 29.) Plug the

AMP STRAPPING

IN OUT

IN OUT

are Straight-Through Ethernet Network cables.

• If you have made your own cables double check them for

secure and proper termination.

Communications Network Cable from the REMOTE IN jack on the fourth amplifier into the REMOTE OUT jack of the

1-Meter Network Cable

AMP STRAPPING

IN OUT

IN OUT

• Did you check the pins (#1 and #8) in the SX Series

amplifiers to make sure they are not bent or damaged?

You have to get the Communications Network working with the third amplifier and update its software before we can proceed with

third amplifier in the chain. Even if you have more than four amps, at this point only the first, second, third and fourth

Additional Network Cable

(Supplied By You)

AMP STRAPPING

IN OUT

IN OUT

the rest of the amplifiers so double check everything. Try a different cable if necessary. Repeat steps 21-27 after double checking your cables and jacks. Once the third amp is successfully updated and in the Communications Network you can move on to step 28.

ones should be connected as the diagram on the right shows.

Additional Network Cable

(Supplied By You)

To Fifith Amplifier

SXRC Remote Control