NOTE: If you take longer than three minutes to plug the Network Cable in from the fourth amplifier (Step 29) the SXRC will time out and return to the scrolling Default Menu. If this happens you will then need to skip Step 30 and return to the Autosearch Menu by following Steps 31-33.

NOTE:

If steps 28-34 worked correctly, you should now have four SX Series amplifiers updated and brought into the SXRC Communications Network, skip to step 35. If not, then read on.

Installation

Step 30.) If the ISIS Display is showing AUTOSEARCH press the ENT key to detect, update and load the second amplifier. Skip to Step 34.

Step 31.) Press the ENT key one time to enter the SXRC Main Menu. The first Main Menu item will be displayed which is AMP ADJ.

ESC

ESC

HOME

ENT

HOME

ENT

If the display came back blinking 3 Units after doing the AUTOSEARCH then there is a problem with the Communications Network.

• Go back and double check your Communication Network

cable between the third and fourth amplifier and make sure it is

inserted properly and ‘snapped’ into place.

• If you have purchased different cables, double check that they

Step 32.) Press the UP or DOWN key until the display reads SXRC SETUP . Press the ENT key to enter the SXRC SETUP Menu.

Step 33.) Press the UP or DOWN key until the display reads AUTOSearch . Press the ENT key to activate the AUTOSEARCH function.

ESC HOME ENT

ESC HOME ENT

are Straight-Through Ethernet Network cables.

• If you have made your own cables double check them for

secure and proper termination.

• Did you check the pins (#1 and #8) in the SX Series

Step 34.) The SXRC is now searching for the fourth amplifier connected to the Communications Network. It will do the exact same sequence (A-P) as in step 13. Once it detects the amplifier it will load the new software into the amplifier and verify the software upload has been successful. The remote will then display how many amplifiers have been detected (4 at this point), successfully updated and brought into the SXRC Communications Network.

AMP1 AMP2

LOCK LEFT SYS RIGHT MUTE GAIN EQ LPF HPF PHASE KOMP

s eaarrcch *

MEM-1 MEM-2 MEM-3 MEM-4

AMP1 AMP2

LOCK LEFT SYS RIGHT MUTE GAIN EQ LPF HPF PHASE KOMP

p rooggrraamm==0 0

MEM-1 MEM-2 MEM-3 MEM-4

AMP1 AMP2

LOCK LEFT SYS RIGHT MUTE GAIN EQ LPF HPF PHASE KOMP

v erriiffy =0 0

MEM-1 MEM-2 MEM-3 MEM-4

AMP1 AMP2

LOCK LEFT SYS RIGHT MUTE GAIN EQ LPF HPF PHASE KOMP

4 unniitts

amplifiers to make sure they are not bent or damaged?

You have to get the Communications Network working with the fourth amplifier and update its software before we can proceed with any additional amplifiers so double check everything. Try a different cable if necessary. Repeat steps 28-34 after double checking your cables and jacks. Once the fourth amp is successfully updated and in the Communications Network you can move on to step 35.

MEM-1 MEM-2 MEM-3 MEM-4

24

SXRC Remote Control

Page 24
Image 24
Fortinet 2 SXRC manual Amplifiers to make sure they are not bent or damaged?