Fostex CR500 5Press the ENTER/YES key again, • Using the MENU dial, • Using the numeric keys

Models: CR500

1 100
Download 100 pages 35.07 Kb
Page 15
Image 15
5)Press the [ENTER/YES] key again.

CD-R/RW MASTER RECORDER CR500 (Preparation before using the CR500)

The display now shows the "SYS SETUP" menu, where "Default File Name • Using the [MENU] dial:" is highlighted.

4)Use the [MENU] dial to scroll through the menu and highlight "Adjust RTC • Using the numeric keys:", then press the [ENTER/YES] key.

The display now shows current clock data which runs in realtime.

5)Press the [ENTER/YES] key again.

The clock data at the moment when pressing the key is hold and now you can edit the clock data.

flashing

6)Edit date/time data using the [MENU] dial or the numeric keys.

• Using the [MENU] dial:

You can edit the value at the cursor (highlighted) position. To move the

cursor, use the [SKIP CURSOR 8)Press the [STOP/HOME] key to exit the MENU mode.<Lithium battery replacement>UDF: Universal Disk Format] key.

• Using the numeric keys:

Each time you press any numeric key, the entered numbers move left from the cursor position.

For example, if you change the currently held data to "06Y 04M 01D 10h 00m 00s", press keys in the following order.

0 -> 6 -> 0 -> 4 -> 0 -> 1 -> 1 -> 0 -> 0 -> 0 -> 0 -> 0

7)After editing date/time data, press the [ENTER/YES] key.

The clock starts running from the entered date/time, while the display returns to the screen which shows current clock data which runs in realtime.

<Note>: If you enter illegal data in step 6) above and press the [ENTER/ YES] key, the display shows "Void data!" and the display returns to the screen where you can edit data. En- ter legal data and press the [ENTER/ YES] key.

8)Press the [STOP/HOME] key to exit the MENU mode.

<Lithium battery replacement>

The unit has an internal lithium battery which is used for driving the realtime clock. The battery life is approximately five years. The battery replacement is done by local Fostex distributor's service department or their authorized service agent.

<Note>: The file creation date of the CR500 is recorded according to the internal realtime clock. However, because "GMT" of "UDF" is set to offset zero, there may be an error when reading the creation date by a PC.

UDF: Universal Disk Format

GMT:Greenwich Mean Time