Device Configuration Commands

 

Command Reference

7.4.7.2Configuration Commands

7.4.7.2.1port-backup

This command is used to enable or disable port backup for a uplink set

Syntax

port-backup <uplinkSetName> no port-backup <uplinkSetName>

<uplinkSetName> - A string associated with uplink set as a convenience. It should be an existing uplink set.

no - This command disable port backup for an existing port group.

Default Setting

None

Command Mode

Global Config

This command is used to set the failback time of port backup for a uplink set.

Syntax

port-backup <uplinkSetName> failback-time <value> no port-backup <uplinkSetName> failback-time

<uplinkSetName> - A string associated with uplink set a convenience. It should be an existing uplink set.

<value> - Time value is range from 1 to 60 seconds. Default value is 60 seconds. no - This command set the failback time to default value for the specific uplink set.

Default Setting

60

Command Mode

Global Config

This command is used to move a port from active-port list to backup-port list.

Syntax

port-backup no port-backup