Device Configuration Commands

 

Command Reference

7.4.11Service VLAN

7.4.11.1Show Commands

This command display the Service VLAN information.

Syntax

show svc-vlan [<svcVlanName>]

<svcVlanName> - The name of Service VLAN which user want to display.

Default Setting

None

Command Mode

Privileged Exec

Display Message

Service VLAN name: This indicates the name of Service VLAN

VLAN ID: The VLAN Identifier of the Service VLAN. The range of the VLAN ID is from 1 to 4094.

Internal Ports: Internal interface, member of that Service VLAN.

Uplink Set Name: Specified the Uplink Set for the external connection.

External Ports: External interface, member of the specified Uplink Set.

7.4.11.2Configuration Commands

7.4.11.2.1svc-vlan

This command is used to create or destroy a Service VLAN.

Syntax

svc-vlan <svcVlanName> <1-4094> <uplinkSetName> no svc-vlan <svcVlanName>

<svcVlanName> - A string associated with Service VLAN as a convenience. <1-4094> - VLAN ID

<uplinkSetName> - which uplink set to be the external connection for this service VLAN.