3)In case of (2) or (3), by pressing (Enter button), LCD display changes to
! | 0 5 | - 1 | L | e n | g | t | h |
= | 1 | 0 / 1 5 | / 2 | 0 |
| m m |
4) At
the document length can be specified.
By pressing (Right arrow button), selection moves from (1) to (3).
By pressing (Left arrow button), selection moves from (3) to (1).
(1)[10] is blinking: The document length difference below 10mm is not detected as an error.
(2)[15] is blinking: The document length difference below 15mm is not detected as an error.
(3)[20] is blinking: The document length difference below 20mm is not detected as an error.
5)Press (Enter button) to confirm the setting.
Press (Exit button), and the LCD display goes back to [Ready] screen.