4.Wipe the translucent rubber part of the Pad ASSY using a lint free cloth moistened with cleaner F1.

Pad (cleaning area)

Pad ASSY

Guide plate

It may take long before the cleaner vaporizes if a large quantity is used.

ATTENTION

When cleaning the scanner parts, dampen a cloth with modest quantities of

 

 

the cleaner. In addition, wipe off the cleaner completely with a soft lint-free

 

cloth to leave no residue on the surface of the cleaned parts.

 

 

5.Install the guide plate in the reverse order of the removal.You should push it down then rotate back, so the installation can be done smoothly.

6.Lower the ADF upper sheet guide carefully.

7.Lift the Upper transport unit to release the safety lock, then lower the unit carefully and push the unit to close it completely.

3

CARE DAILY

3.2 Cleaning the Pad 3-7