Fujitsu MAS3735, MAP3367, MAP3147, MAP3735, MAS3367 specifications Data Access Commands Read

Models: MAP3735 MAP3147 MAS3367 MAP3367 MAS3735

1 290
Download 290 pages 28.72 Kb
Page 127
Image 127

3.2 Data Access Commands

3.2Data Access Commands

3.2.1READ (08)

Bit

Byte

7

6

5

4

3

2

1

0

0

X‘08’

1

LUN

Logical Block Address (MSB)

2

Logical Block Address

3

Logical Block Address (LSB)

4

Transfer Block Count

5

0

0

0

0

0

0

0

Link

This command reads the number of blocks of data in continuous logical data blocks specified in the "Transfer block count" field with the logical data block on the disk media specified in the "Logical block address" field in the CDB as the top.

The transfer block count can be specified up to a maximum of 256 logical data blocks. When zero is specified in the "Transfer block count" field in byte 4 of the CDB, it specifies transfer of 256 logical data blocks and when a value other than zero is specified, it specifies the number of logical data blocks that should be transferred.

When transfer of multiple data blocks is instructed by this command, when the data blocks which are to be processed come to a track boundary, cylinder boundary or zone boundary, a head switch or cylinder switch is executed automatically and reading of the specified number of blocks is performed.

When the specifications in the "Logical block address" field and "Transfer block count" field in the CDB exceed the maximum logical block address in the IDD, that command is terminated with a CHECK CONDITION status (ILLEGAL REQUEST [=5] / Logical block address out of range [=21- 00]) and the reading of data from the disk media is not executed.

Error recovery processing during execution of this command can be specified by the MODE SELECT parameter. If retry processing and data correction processing are not prohibited, when this command is completed normally, or when it is completed with a "RECOVERED ERROR [=1]" sense key report, the data transferred to the INIT by this command are error free. When a correctable error check is detected, the IDD first corrects the data errors in the data buffer, then transfers those data to the INIT.

When disconnect processing is permitted, the starting timing for reconnection processing in order to execute data transfer on the SCSI bus can be specified by the MODE SELECT parameter (buffer full ratio). Also, if the Look-Ahead cache feature is permitted, a caching operation is performed using the IDD's data buffer by this command. See Chapter 2, "Data Buffer Management," concerning details of data buffer operation and the Look-Ahead cache feature.

C141-E167

3 - 65

Page 127
Image 127
Fujitsu MAS3735, MAP3367, MAP3147, MAP3735, MAS3367 specifications Data Access Commands Read