Sense Data Error Recovery Methods

 

 

Table 5.2

Sense and subsense codes (3 of 5)

 

 

 

 

 

 

 

C*

Q*

Name

 

Explanation

Sense

 

 

 

 

 

key

1F

00

Partial Defect List Transfer

Read Defect Data command (37h) cannot transfer all the Defect data

1

 

 

 

in the target because the numbers of defect exceeded the maximum.

 

 

 

 

 

 

20

00

Invalid command

CDB byte 0 (operation code) is illegal.

5

 

 

operation code

 

 

 

 

 

 

 

 

21

00

Logical block address out

A logical block address which exceeds the drive's maximum value

5

 

 

of range

was specified.

 

 

 

 

 

 

24

00

Invalid field in CDB

There is an error in a specification in the CDB.

5

 

 

 

 

 

25

00

Logical unit not supported

An illegal LUN was specified.

5

 

 

 

 

 

26

00

Invalid field in parameter

There is an error in the parameter list specifications transferred from

5

 

 

list

the INIT during command execution.

 

 

 

 

 

 

 

04

Invalid Release of

There is unmatched valid reservation status in the parameter list

5

 

 

Persistent Reservation

specifications

 

 

 

 

 

 

27

00

Write protected

A write operation was attempted in a write protected area. Or a

7

 

 

 

write operation is prohibited at the external operation panel.

 

 

 

 

 

 

29

01

Power on occurred

Power On occurred.

6

 

 

 

 

 

 

02

SCSI reset occurred

A SCSI RESET was received.

6

 

 

 

 

 

 

03

TARGET RESET message

A TARGET RESET message was received.

6

 

 

occurred

 

 

 

 

 

 

 

 

 

05

Transciever mode changed

Transciever mode was changed to Single-Ended mode.

6

 

 

to Single-Ended

 

 

 

 

 

 

 

 

 

06

Transciever mode changed

Transiever mode was changed to LVD mode.

6

 

 

to LVD

 

 

 

 

 

 

 

 

2A

01

Mode parameter changed

The MODE SELECT parameter values were changed by another INIT.

6

 

 

 

 

 

 

03

Reservations preempted

A persistent reserve state was cleared by another INIT.

6

 

 

 

 

 

 

04

Reservations released

A persistent reserve state was released

6

 

 

 

 

 

 

05

Registrations preempted

A persistent reserve state was prempted by another INIT.

6

 

 

 

 

 

2F

00

Command cleared by

A command was forcibly terminated by another INIT during

6

 

 

another INIT

execution or queuing.

 

 

 

 

• By a CLEAR QUEUE message

 

 

 

 

• The sense hold state was entered when the QErr bit was set on "1."

 

 

 

 

• The DQue bit was changed from "0" to "1."

 

 

 

 

 

 

31

00

Medium format corrupted

The media format is different from the original format. (The media

3

 

 

 

was not formatted after the data format specification was changed by

 

 

 

 

the MODE SELECT command.)

 

 

 

 

 

 

 

01

FORMAT command failed

For some reason, formatting cannot be completed and reformatting

3

 

 

 

is necessary.

 

32

00

No defect spare location

No usable alternate block area exists. Or alternate block processing

4

 

 

available

cannot be performed due to control table overflow.

 

 

 

 

 

 

 

01

Defect list update failure

Updating of the defect list (G List) failed.

4

 

 

 

 

 

37

00

Rounded parameter

Rounding processing of the MODE SELECT parameter specified by

1

 

 

 

the command was performed.

 

 

 

 

 

 

 

*C: Sense Code, Q: Sub-sense Code