Fujitsu MAP3367, MAP3147, MAS3735, MAP3735 Specified cycle count over device lifetime Page 0E, Code

Models: MAP3735 MAP3147 MAS3367 MAP3367 MAS3735

1 290
Download 290 pages 28.72 Kb
Page 230
Image 230

Parameter Data Formats

The Accounting date specified by parameter code 0002h is a parameter that may be savable using a LOG SELECT command to indicate when the device was placed in service. If the parameter is not yet set or is not settable, the default value placed in the parameter field shall be 6 ASCII blank characters (20h). The field shall not be checked for validity by the device server.

4.2.8.3 Specified cycle count over device lifetime (Page 0E, Code 0003)

 

Bit

7

6

 

5

4

3

 

2

1

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

(MSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X'0003' (Parameter code)

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

(Specified Cycle Count Over Device Lifetime)

(LSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

DU

DS

 

TSD

ETC

 

TMC

LBIN

LP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

 

0

0

0

0

1

1

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

X'04' (Parameter Length)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

(MSB)

 

 

 

 

 

 

 

 

 

9

Specified Cycle Count Over Device Lifetime (4-byte binary number)

10

11

(LSB)

The Specified cycle count over device lifetime is a parameter provided by the device sever. The specified cycle count over device lifetime parameter shall not be savable by the application client using the LOG SELECT command. The parameter value is a 4-byte binary number. The value indicates how operation or reliability outside the limits specified by the manufacture of the device.

4.2.8.4 Start-stop cycle counter (Page 0E, Code 0004)

 

Bit

7

6

 

5

4

3

 

2

1

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

(MSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

X'0004' (Parameter code)

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

(Accumulated Start-Stop Cycles)

 

(LSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

DU

DS

 

TSD

ETC

 

TMC

LBIN

LP

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

 

0

0

0

0

1

1

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

X'04' (Parameter Length)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

(MSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

Accumulated Start-Stop Cycles (4-byte binary number)

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

(LSB)

 

 

 

 

 

 

 

 

 

 

 

 

4 - 54