Fujitsu MAS3735, MAP3367, MAP3147, MAP3735, MAS3367 specifications Mode Sense Data Type Specifications

Models: MAP3735 MAP3147 MAS3367 MAP3367 MAS3735

1 290
Download 290 pages 28.72 Kb
Page 92
Image 92

Command Specifications

 

Table 3.1

MODE SENSE Data Type Specifications

 

 

 

PC

 

Type of Parameter Transferred to the INIT

 

 

 

00

Current Values:

 

 

Reports each "Current" parameter value. The "Current" values are either of the following values.

 

Values specified by a MODE SELECT or MODE SELECT EXTENDED command which is finally

 

normally terminated.

 

 

When a MODE SELECT or MODE SELECT EXTENDED command is not executed after the power is

 

switched on, after a RESET condition or after a BUS DEVICE RESET message issued by any INIT is

 

received, the same values as "Save" values. However, if "Save" values do not exist for parameters

 

other than those on Page 3 and Page 4 (excluding byte 17), the same values as "Default" values.

 

 

 

01

Variable Values:

 

 

The INIT reports variable parameter fields and parameter bits through the MODE SELECT or MODE

 

SELECT EXTENDED command. A "1" is reported in the variable fields and bit positions in each page

 

descriptor and "0" is reported in the fields and bit positions which cannot be changed. See the description

 

of each page descriptor for the MODE SELECT command (Section 3.1.5) concerning the variability of

 

each parameter.

 

 

 

 

10

Default Values:

 

 

Reports the "Default" value of each parameter. See the description of each page descriptor for the MODE

 

SELECT command (Section 3.1.5) concerning the actual default value of each parameter.

 

 

 

11

Save Values:

 

Reports the "Save" value of each parameter. The "Save" values are either of the following values.

For parameters other than those on Page 3 and Page 4 (excluding byte 17), these are the values specified in a MODE SELECT or MODE SELECT EXTENDED command in which the "SP" bit after the final execution is completed is "1." When a MODE SELECT or MODE SELECT EXTENDED command in which the "SP" bit is "1" is not executed (when "Save" values do not exist), these are the same values as the "Default" values.

The values in the parameters in Page 3 and Page 4 (excluding byte 17) are the values save to the disk media during execution of the FORMAT UNIT command.

The "Transfer Byte Length" field in the CDB specifies the total number of bytes of MODE SENSE data which can be transferred to the INIT by this command. The IDD transfers the number of bytes of all the MODE SENSE data specified in the "Page code" field or the portion of MODE SENSE data with the length specified in the "Transfer Byte Length" field, whichever is smaller. When zero is specified in the "Transfer Byte Length" field, this command is terminated without anything being transferred.

Figure 3.10 shows the data configuration in the parameter list (MODE SENSE data) transferred to the INIT by this command. The parameter list consists of a 4-byte header, an 8-byte block descriptor and one or more page descriptors, specified in the CDB, which are transferred in order. However, when "1" is specified in the DBD bit of the CDB, the block descriptor is not transferred. Also, when X '00' is specified in the "Page code" field of the CDB, the page descriptor is not transferred.

3 - 30

C141-E167

Page 92
Image 92
Fujitsu MAS3735, MAP3367, MAP3147, MAP3735, MAS3367 specifications Mode Sense Data Type Specifications