Parameter Data Formats

 

Bit

7

6

5

 

4

 

3

2

1

 

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

0

0

0

 

0

1

0

0

 

 

 

 

 

 

 

 

1

 

 

X‘16’, X‘12’ or X‘0A’ (Page Length)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-4

 

 

 

Cylinder Count

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

 

X‘00xxxx’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable

 

 

 

X‘000000’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

Number of Heads

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

 

X‘00xx’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable

 

 

 

X‘0000’

 

 

 

 

 

 

 

 

 

 

 

 

 

6-8

 

 

"Write Precompensation" Starting Cylinder

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

 

X‘000000’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable

 

 

 

X’000000’

 

 

 

 

 

9-11

 

 

"Reduced Write Current" Starting Cylinder

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

 

X‘000000’

 

 

 

 

 

 

Variable

 

 

 

X‘000000’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12-13

 

 

 

Drive Step Rate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

 

X‘0000’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable

 

 

 

X‘0000’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14-16

 

 

 

Landing Zone Cylinder

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

 

X‘000000’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable

 

 

 

X‘000000’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

0

0

0

0

 

0

0

 

RPL

 

 

 

 

 

 

 

 

 

 

 

 

Default

0

0

0

0

 

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

Variable

0

0

0

0

 

0

0

0

0

 

 

 

 

 

 

 

 

18

 

 

Rotational Synchronization Offset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

 

 

X‘00’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable

 

 

 

 

X‘00’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

 

 

 

X‘00’ (Reserved)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20-21

 

 

 

Rotational Speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

 

X’2729’ or X’3A98’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable

 

 

 

X‘0000’

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22-23

 

 

 

X‘0000’ (Reserved)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(See the "Note")

(10,025 rpm or

15,000 rpm)

Figure 4.4 MODE SELECT parameters: drive parameters

Note:

When transfer of this page is requested by the MODE SENSE or MODE SENSE EXTENDED command, the IDD reports X '16' as the page length. However, in the MODE SELECT and MODE SELECT EXTENDED commands, if either X '16,' X '12' or X '0A' is specified, it is treated as if the IDD has specified the correct page length. The X '12' and X '0A' page lengths have been included in consideration of compatibility with previous models, but it is recommended that the INIT use the X '16' page length to support expanded specifications in the future.