Fujitsu MAP3367, MAP3147, MAS3735, MAP3735, MAS3367 specifications Command Specifications

Models: MAP3735 MAP3147 MAS3367 MAP3367 MAS3735

1 290
Download 290 pages 28.72 Kb
Page 80
Image 80

Command Specifications

*Set at shipping time

The IDD ignores this specification and operates with the settings specified at shipping.

f)ACE (AIP checking enabled)

This specifies whether or not it is permitted to check AIP (Asynchronous Information Protection).

"1" (Permitted): Permitting check

"0"*(Prohibited): Prohibiting check

*Set at shipping time

The IDD ignores this specification and operates with the settings specified at shipping.

g)AGD (AIP generation disabled)

This specifies whether or not it is permitted to generate AIP (Asynchronous Information Protection).

"1" * (Prohibited): Prohibited generation

"0" (Permitted): Permitted generation

*Set at shipping time

The IDD ignores this specification and operates with the settings specified at shipping.

h)RTD (reselection timeout delay)

This specifies the reselection timeout delay time.

Bit 1

Bit 0

 

Reselection Time-out Delay

 

 

 

 

0

0

250

[ms]*

0

1

3

[ms]

1

0

Reserved

1

1

Reserved

*Set at shipping time

i)Spindle motor start delay time

This specifies the time after power on until the motor starts.

The IDD's motor starts after [(value specified in this parameter) x (IDD's SCSI ID x 0.1)] seconds from the power is switched on. If X '00' is specified in this parameter, the motor starts immediately after the power is switched on, no matter what SCSI ID is set in the IDD. Also, the IDD starts the motor immediately no matter what value is specified in this parameter.

This parameter is enabled only when set in the "Auto Motor Start Mode" with a setting terminal.

3 - 18