Command Specifications
b.G List (grown list) bit
When this bit is “1,” it indicates that G List defect data are included in the defect descriptor list that is actually transferred to the INIT. When it is “0,” it indicates that the G List defect data are not included. See 3) of item (2).)
c.Defect list format
This field indicates the description format of the defect descriptor list that is actually transferred to the INIT. It is possible for the IDD to transfer defect data in 3 different formats which it can specify in the CDB, and the values in this field are the same as the values specified in the “Defect List Format” field in the CDB.
d.Defect list length
This field follows the
(2)Defect descriptor list
The data transferred after the
See the description of the FORMAT UNIT command (Section 3.3.1) concerning the configuration and contents of the “Defect descriptor” in each format.
Notes: Precautions for use of command
1.When “1” is specified in both the “P List” bit and the “G List” bit in the CDB, and transfer of both the P List and G List is requested, the IDD first of all transfers the P List, then transfers the G List afterward (merging of the defect information in the two lists is not performed).
2.When “0” is specified in both the “PList” bit and the “GList” bit in the CDB, only the header is transferred by that command, but the following information is shown in the header at this time.
•PList bit: “0”
•GList bit: “0”
3 - 90 |