4.1 Mode Parameters

READ

WRITE

READ EXTENDED

WRITE AND VERIFY (Write operation)

READ LONG

WRITE EXTENDED

SEND DIAGNOSTIC (Write/read test)

WRITE LONG

a.AWRE (automatic write reallocation enabled)

"1" : An "automatic alternate block allocation processing" operation is specified during execution of a write operation.

"0" : An "automatic alternate block allocation processing" operation is prohibited during execution of a write operation.

Automatic alternate block allocation processing is explained in Section 5.3.2.

b.ARRE (automatic read reallocation enable)

"1" : An "automatic alternate block allocation processing" operation is specified during execution of a read operation.

"0" : An "automatic alternate block allocation processing" operation is prohibited during execution of a read operation.

Automatic alternate block allocation processing is explained in Section 5.3.2.

c.TB (transfer block)

"1" : Data blocks which contain errors that are impossible to correct are transferred to the INIT during a read operation.

"0" : Data blocks which contain errors that are impossible to correct are not transferred to the INIT during a read operation.

d.RC (read continuous)

This bit specifies continuous transfer of all the data requested by a command unaccompanied by a delay for executing error recovery processing.

e.EER (enable early recovery)

"1" : When a correctable data check has been detected, data correction according to the ECC is applied immediately without executing retry (rereading) up to the number of times specified in the "Number of retries during READ" parameter.

"0" : When a correctable data check has been detected, retry (rereading) is executed up to the number of times specified in the "Number of retries during READ" parameter, then data correction according to the ECC is applied if possible.

The IDD disregards this bit and operates according to the default value (=1).