SK-91F467-FLEXRAY V1.1

Jumpers and Switches

JP63 Connects FlexRay channel B RS-485 transceiver output B to Sub-D-9 connector (X6)

JP67 Connects FlexRay channel B RS-485 transceiver output A to Sub-D-9 connector (X6)

JP59, JP62 Connects RS-485 termination network to signal lines at FlexRay channel B

JP73 Connects FT1080 module CH-B EN to configuration switch S6

JP74 Connects FT1080 module CH-B WAKE to configuration switch S6

JP75 Connects FT1080 module CH-B nSTB to configuration switch S6

JP76 Connects FT1080 module CH-B nERR to MCU port P14_7

JP77 Connects FT1080 module CH-B VBat to VBat (input voltage of the starter kit)

 

Jumper

 

Setting

 

Description

 

 

JP61

 

ON (closed)

 

TXDB connected to RS-485 transceiver

 

 

 

OFF (open)

 

TXDB not connected to RS-485 transceiver

 

 

 

 

 

JP66

 

ON (closed)

 

TXENB connected to RS-485 transceiver

 

 

 

OFF (open)

 

TXENB not connected to RS-485 transceiver

 

 

 

 

 

JP70

 

ON (closed)

 

RXDB connected to RS-485 transceiver

 

 

 

OFF (open)

 

RXDB not connected to RS-485 transceiver

 

 

 

 

 

JP63

 

ON (closed)

 

CH-B RS-485 output B connected to X6

 

 

 

OFF (open)

 

CH-B RS-485 output B not connected to X6

 

 

 

 

 

JP67

 

ON (closed)

 

CH-B RS-485 output A connected to X6

 

 

 

OFF (open)

 

CH-B RS-485 output A not connected to X6

 

 

 

 

 

JP59, JP62

 

ON (closed)

 

Line termination connected to CH-B RS-485

 

 

 

OFF (open)

 

Line termination not connected to CH-B RS-485

 

 

 

 

 

JP73

 

ON (closed)

 

CH-B FT1080 EN connected to S6

 

 

 

OFF (open)

 

CH-B FT1080 EN connected to S6

 

 

 

 

 

JP74

 

ON (closed)

 

CH-B FT1080 WAKE connected to S6

 

 

 

OFF (open)

 

CH-B FT1080 WAKE connected to S6

 

 

 

 

 

JP75

 

ON (closed)

 

CH-B FT1080 nSTB connected to S6

 

 

 

OFF (open)

 

CH-B FT1080 nSTB connected to S6

 

 

 

 

 

JP76

 

ON (closed)

 

CH-B FT1080 nERR connected to MCU P14_7

 

 

OFF (open)

 

CH-B FT1080 nERR not connected to MCU P14_7

 

 

 

 

 

 

 

JP77

 

ON (closed)

 

VBat is connected to FT1080 CH-B

 

 

 

OFF (open)

 

VBat is not connected to FT1080 CH-B

 

 

 

 

Default: grey

Table 3-12: FlexRay CH-B Configuration