Interface

(25) STANDBY (X’96’ or X’E2’)

Upon receipt of this command, the device sets the BSY bit of the Status register and enters the standby mode. The device then clears the BSY bit and generates an interrupt. The device generates an interrupt even if the device has not fully entered the standby mode. If the device has already spun down, the spin-down sequence is not implemented.

By using this command, the automatic power-down function is enabled and the timer starts the countdown when the device returns to idle mode. When the timer value reaches 0 (a specified time has padded), the device enters standby mode.

Under the standby mode, the spindle motor is stopped. Thus, when the command involving a seek such as the READ SECTOR(s) command is received, the device processes the command after driving the spindle motor.

At command issuance (I/O registers setting contents)

1F7H(CM)

X’96’ or X’E2’

 

 

 

 

 

 

 

 

1F6H(DH)

x

x

x

DV

xx

1F5H(CH)

xx

 

 

 

 

1F4H(CL)

xx

 

 

 

 

1F3H(SN)

xx

 

 

 

 

1F2H(SC)

Period of timer

 

 

1F1H(FR)

xx

 

 

 

 

At command completion (I/O registers contents to be read)

1F7H(ST)

Status information

 

 

 

 

 

 

 

 

1F6H(DH)

x

x

x

DV

xx

1F5H(CH)

xx

 

 

 

 

1F4H(CL)

xx

 

 

 

 

1F3H(SN)

xx

 

 

 

 

1F2H(SC)

xx

 

 

 

 

1F1H(ER)

Error information

 

 

 

 

 

 

 

 

5-60

C141-E120-02EN

Page 136
Image 136