5.6 Timing

5.6 Timing

5.6.1 PIO data transfer

Figure 5.9 shows of the data transfer timing between the device and the host system.

t0

Addresses

 

t1

 

 

 

 

 

 

t2

 

t9

 

 

 

DIOR-/DIOW-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t2i

 

 

Write data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DD0-DD15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t3

t4

 

 

 

Read data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DD0-DD15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t5

 

 

t6

 

 

 

 

IORDY

t10

 

 

 

 

 

 

 

t11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Symbol

Timing parameter

 

 

 

Min.

Max.

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t0

Cycle time

 

 

 

 

 

 

 

 

 

 

 

 

 

120

ns

 

 

 

 

 

 

 

 

t1

Data register selection setup time for DIOR-/DIOW-

 

 

 

25

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t2

Pulse width of DIOR-/DIOW-

 

 

 

 

 

 

 

 

 

 

 

 

 

70

ns

 

 

 

 

 

 

 

 

t2i

Recovery time of DIOR-/DIOW-

 

 

 

25

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t3

Data setup time for DIOW-

 

 

 

 

 

 

 

 

 

 

 

 

 

20

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t4

Data hold time for DIOW-

 

 

 

 

 

 

 

 

 

 

 

 

 

10

ns

 

 

 

 

 

 

 

 

t5

Time from DIOR- assertion to read data available

 

 

 

50

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t6

Data hold time for DIOR-

 

 

 

 

 

 

 

 

 

 

 

 

 

5

ns

 

 

 

 

 

 

 

 

t9

Data register selection hold time for DIOR-/DIOW-

 

 

 

10

ns

 

 

 

 

 

t10

Time from DIOR-/DIOW- assertion to IORDY "low" level

35

ns

 

 

 

 

 

t11

Time from validity of read data to IORDY "high" level

0

ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t12

Pulse width of IORDY

 

 

 

 

 

 

 

 

 

 

 

 

 

1,250

ns

 

 

 

 

 

 

 

Figure 5.9

PIO data transfer timing

 

 

 

C141-E120-02EN

5-111

Page 187
Image 187
Fujitsu MHN2200AT, MHN2150AT, MHN2100AT, MHN2300AT manual Timing, PIO data transfer timing