5.3 Host Commands

At command issuance (I/O registers setting contents)

1F7H(CM)

0

0

1

1

1

1

0

0

1F6H(DH)

x

L

x

DV

Start head No. / LBA

 

 

 

 

 

 

[MSB]

 

 

 

 

 

 

 

 

 

 

 

 

1F5H(CH)

Start cylinder No. [MSB] / LBA

 

 

 

1F4H(CL)

Start cylinder No. [LSB] / LBA

 

 

 

1F3H(SN)

Start sector No. / LBA [LSB]

 

 

 

1F2H(SC)

Transfer sector count

 

 

 

 

1F1H(FR)

xx

 

 

 

 

 

 

 

At command completion (I/O registers contents to be read)

1F7H(ST)

Status information

 

 

1F6H(DH)

x

 

L

x

DV

End head No. / LBA [MSB]

 

 

 

 

 

 

1F5H(CH)

End cylinder No. [MSB] / LBA

1F4H(CL)

End cylinder No. [LSB] / LBA

1F3H(SN)

End sector No. / LBA [LSB]

1F2H(SC)

00 (*1)

 

 

 

 

1F1H(ER)

Error information

 

 

 

 

 

 

 

 

 

*1 If the command is terminated due to an error, the remaining number of sectors of which data was not transferred is set in this register.

(9) RECALIBRATE (X’1x’, x: X’0’ to X’F’)

This command performs the calibration. Upon receipt of this command, the device sets BSY bit of the Status register and performs a calibration. When the device completes the calibration, the device updates the Status register, clears the BSY bit, and generates an interrupt.

This command can be issued in the LBA mode.