5.3 Host Commands

If an error occurs during multiple sector write operation, the write operation is terminated at the sector where the error occurred. Command block registers contain the cylinder, the head, the sector addresses (in the CHS mode) or the logical block address (in the LBA mode) of the sector where the error occurred.

At command issuance (I/O registers setting contents)

1F7H(CM)

0

0

1

1

0

0

0

R

1F6H(DH)

x

L

x

DV

Start head No. / LBA

 

 

 

 

 

 

[MSB]

 

 

 

 

 

 

 

 

 

 

 

 

1F5H(CH)

Start cylinder No. [MSB] / LBA

 

 

 

1F4H(CL)

Start cylinder No. [LSB] / LBA

 

 

 

1F3H(SN)

Start sector No. / LBA [LSB]

 

 

 

1F2H(SC)

Transfer sector count

 

 

 

 

1F1H(FR)

xx

 

 

 

 

 

 

 

At command completion (I/O registers contents to be read)

1F7H(ST)

Status information

 

 

 

 

 

 

 

 

 

1F6H(DH)

x

 

L

x

DV

End head No. / LBA [MSB]

1F5H(CH)

End cylinder No. [MSB] / LBA

1F4H(CL)

End cylinder No. [LSB] / LBA

1F3H(SN)

End sector No. / LBA [LSB]

1F2H(SC)

00 (*1)

 

 

 

 

1F1H(ER)

Error information

 

 

*1 If the command is terminated due to an error, the remaining number of sectors of which data was not transferred is set in this register.