Interface
Table 5.11 SMART error log data format
Byte |
|
|
| Item | |
|
|
|
|
| |
00 | Error log version number |
|
| ||
|
|
|
|
|
|
01 | Error log index |
|
|
| |
|
|
|
|
|
|
02 | Error log 1 |
| Command Data 1 |
| Device Control register |
|
|
|
|
|
|
03 |
|
|
|
| Features register |
|
|
|
|
|
|
04 |
|
|
|
| Sector Count register |
|
|
|
|
|
|
05 |
|
|
|
| Sector Number register |
|
|
|
|
|
|
06 |
|
|
|
| Cylinder Low register |
|
|
|
|
|
|
07 |
|
|
|
| Cylinder High register |
|
|
|
|
|
|
08 |
|
|
|
| Device/Head register |
|
|
|
|
|
|
09 |
|
|
|
| Command register |
|
|
|
|
|
|
0A to 0D |
|
|
|
| Elapsed time [ms] from the point when |
|
|
|
|
| the power is turned on until command |
|
|
|
|
| reception |
|
|
|
|
|
|
0E to 3D |
|
| Command Data 2 |
| (The format of each type of command |
|
|
| to 5 |
| data is the same as that of byte 02 to |
|
|
|
|
| 0D.) |
|
|
|
|
|
|
3E |
|
| Error data |
| Reserved |
|
|
|
|
|
|
3F |
|
|
|
| Error register |
|
|
|
|
|
|
40 |
|
|
|
| Sector Count register |
|
|
|
|
|
|
41 |
|
|
|
| Sector Number register |
|
|
|
|
|
|
42 |
|
|
|
| Cylinder Low register |
|
|
|
|
|
|
43 |
|
|
|
| Cylinder High register |
|
|
|
|
|
|
44 | Error log 1 |
| Error data |
| Device/Head register |
|
|
|
|
|
|
45 |
|
|
|
| Status register |
|
|
|
|
|
|
46 to 58 |
|
|
|
| Vendor unique |
|
|
|
|
|
|
59 |
|
|
|
| Status |
|
|
|
|
|
|
5A, 5B |
|
|
|
| Total power on time [hour] |
|
|
|
|
| |
5C to 1C3 | Error log 2 to |
| (The format of each error log is the same as Byte 02 to 5B.) | ||
| Error log 5 |
|
|
|
|
|
|
| |||
1C4, 1C5 | Number of unrecoverable errors that have occurred. | ||||
|
|
|
|
| |
1C6 to 1FE | Reserved |
|
|
| |
|
|
|
|
| |
1FF | Check sum |
|
|
| |
|
|
|
|
|
|