Interface
Self-test | Meaning |
execution status | |
| |
0 | Self-test has been completed normally or has not been |
| executed. |
| |
1 | Self-test has been stopped by the host computer. |
| |
2 | Self-test has been suspended by hard or soft reset. |
| |
3 | Self-test has been aborted by a fatal error. |
| |
4 | Self-test has been completed abnormally by an unknown |
| meaning. |
| |
5 | Self-test has been completed abnormally by write test. |
| |
6 | Self-test has been completed abnormally by serbo test. |
| |
7 | Self-test has been completed abnormally by read test. |
| |
8 to 14 | Reserved |
| |
15 | Self-test is in progress. |
| |
•Off-line data collection capability
Indicates the method of off-line data collection carried out by the drive. If the off-line data collection capability is 0, it indicates that off-line data collection is not supported.
0Indicates that Execute Off-Line Immediate is supported.
1Vendor unique
2Indicates that off-line data collection being executed is aborted when a new command is received.
3Indicates that supports off-line read scan function.
4Indicates that supports self-test function.
Failure prediction capability flag
Bit 0: The attribute value data is saved to a media before the device enters power saving mode.
Bit 1: The device automatically saves the attribute value data to a media after the previously set operation.
Bits 2 to 15: Reserved bits
Error logging capability
Bit 0: Indicates that error logging function.
Bits 1 to 7: Reserved bits